Specifications

E-500/E-501 Series PZT Servo Controllers User Manual PZ 62E
Release 2.15.1 www.pi.ws Page 42
5.8. E-509 Signal Conditioner / Servo-Controller Module
INFORMATION
See the E-509 User Manual (PZ77) for a detailed description.
See also the User Manuals for the E-802 servo-controller submodule (with all E-509
versions) and the E-801 sensor submodule (only with LVDT and strain gauge sensor
versions).
5.8.1. Front Panel Elements of Modules for Dual-Electrode Capacitive Sensors
Fig. 19: E-509.C1A sensor
/ servo controller
Fig. 20: E-509.C2A
sensor / servo controller
Fig. 21: E-509.C3A
sensor / servo controller
Labeling Type Function
T
LEMO
EPL.00.250.NTD
Input for the Target sensor signal from the piezo stage.
P
LEMO
EPL.00.250.NTD
Input for the Probe sensor signal from the piezo stage.
ZERO
Trim potentiometer A trimmer adjustment tool can be used on the ZERO potentiometer
for a zero-point adjustment of the sensor. A zero-point adjustment
can be necessary after longer operation (changes in temperature)
or if the load on the piezo stage is changed.
OFL
LED
Yellow/off
Overflow state:
Yellow: Overflow condition, i.e. the amplifier is near its range
limit.
Off: No overflow condition
When the OFL LED comes on, a zero-point adjustment of the
sensor can be necessary. See p. 17 and the E-509 User Manual
(PZ77E) for details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com