Specifications
E-500/E-501 Series PZT Servo Controllers   User Manual PZ 62E 
Release 2.15.1  www.pi.ws   Page 42 
5.8.  E-509 Signal Conditioner / Servo-Controller Module 
INFORMATION 
    See the E-509 User Manual (PZ77) for a detailed description. 
  See also the User Manuals for the E-802 servo-controller submodule (with all E-509 
versions) and the E-801 sensor submodule (only with LVDT and strain gauge sensor 
versions). 
5.8.1.  Front Panel Elements of Modules for Dual-Electrode Capacitive Sensors 
Fig. 19: E-509.C1A sensor 
/ servo controller 
Fig. 20: E-509.C2A 
sensor / servo controller 
Fig. 21: E-509.C3A 
sensor / servo controller 
Labeling  Type  Function 
T 
LEMO 
EPL.00.250.NTD 
Input for the Target sensor signal from the piezo stage. 
P 
LEMO 
EPL.00.250.NTD 
Input for the Probe sensor signal from the piezo stage. 
ZERO 
Trim potentiometer  A trimmer adjustment tool can be used on the ZERO potentiometer 
for a zero-point adjustment of the sensor. A zero-point adjustment 
can be necessary after longer operation (changes in temperature) 
or if the load on the piezo stage is changed. 
OFL 
LED 
Yellow/off 
Overflow state: 
  Yellow: Overflow condition, i.e. the amplifier is near its range 
limit. 
  Off: No overflow condition 
When the OFL LED comes on, a zero-point adjustment of the 
sensor can be necessary. See p. 17 and the E-509 User Manual 
(PZ77E) for details. 