A.4.3 Onboard EIDE Connector CON5 Pinout
A 2.5” HardDisk may be connected directly to the CP302 I/O module. The HDD is
connected to a 44-pin connector.
Table A-5: Pinout of the AT 44-pin EIDE Connector CON5
Pin Signal Function In/Out
1 IDERESET Reset HD Out 
2 GND Ground signal --
3 HD7 HD data 7 In/Out
4 HD8 HD data 8 In/Out
5 HD6 HD data 6 In/Out
6 HD9 HD data 9 In/Out
7 HD5 HD data 5 In/Out
8 HD10 HD data 10 In/Out
9 HD4 HD data 4 In/Out
10 HD11 HD data 11 In/Out
11 HD3 HD data 3 In/Out
12 HD12 HD data 12 In/Out
13 HD2 HD data 2 In/Out
14 HD13 HD data 13 In/Out
15 HD1 HD data 1 In/Out
16 HD14 HD data 14 In/Out
17 HD0 HD data 0 In/Out
18 HD15 HD data 15 In/Out
19 GND Ground signal --
20 N/C -- --
21 IDEDRQ DMA request In
22 GND Ground signal --
23 IOW I/O write Out
24 GND Ground signal --
25 IOR I/O read Out
Table continued on following page