Specifications
CP302 CP-RIO3-01 Rear I/O Module
ID 21112, Rev. 05 Page D - 11® PEP Modular Computers GmbH
D.4.7 Fan Control Interface (optional)
A fan for CPU cooling can be connected via the power connector CON9.
D4.7.1 Fan Control Connector CON9 Pinout
D.4.8 EIDE Interface
D.4.8.1 EIDE Connector EIDE2 (CON7) Pinout
The following table sets out the pin numbers of connector CON7 and sets out its
corresponding signal names and functions.
Table D-6: Fan Control Connector CON9 Pinout
Pin Function
1 Ground
2 5V Fan Supply Voltage at a maximum current of 300 mA
3 Fansense
Table D-7: Pinout of AT Standard Connector EIDE2
Pin Signal Function In/Out
1 IDERESET Reset HD Out
2 GND Ground signal --
3 HD7 HD data 7 In/Out
4 HD8 HD data 8 In/Out
5 HD6 HD data 6 In/Out
6 HD9 HD data 9 In/Out
7 HD5 HD data 5 In/Out
8 HD10 HD data 10 In/Out
9 HD4 HD data 4 In/Out
10 HD11 HD data 11 In/Out
11 HD3 HD data 3 In/Out
12 HD12 HD data 12 In/Out
13 HD2 HD data 2 In/Out
Table continued on following page
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com