Specifications

17
F500 Operation Manual/SECTION 1
Basic operating procedures
SECTION 1
Menu Operations
SECTION 1
Screen Displays
The Controller is operated by selecting functions from menus displayed on the
screen.Familiarize yourself with each function before operating the Controller.
*1 Mode
0.Scn 0=SET=
0.Camera image
1.
ENT:Set SFT+ESC:Edit
Scene Number
There are 32 screens. Setting
different measurement
conditions for each one allows
easy switching between
different setups.
Cursor Keys
The cursor is moved to the
desired function by pressing
the Cursor Keys.
A processing item is
set for each unit.
When a measurement command is
input, units are processed in order
from unit 0.
Mode (*1)
The current operating mode is
displayed.
The type of image shown on the
screen is displayed in Monitor and
Run Modes.
SECTION 5
System Settings p.30
Key Operations
Displays special key combinations at the bottom of the screen
when available.
“SFT” refers to the SHIFT Key. “SFT+ESC” indicates that the
ESC Key should be pressed while the SHIFT Key is pressed.
Sometimes the SFT Key display is abbreviated to just “S”.
Units
Display Contents
Setting Used to set the inspection conditions.
MON
(Monitor)
Used to check whether inspections are being performed correctly under the set inspection
conditions.
The measurement results are displayed on the monitor only. The results cannot be output
to external devices.
Measurement Performs inspection. The measurement results are output to an external device via the
parallel interface or serial interface.
SYS (System) Used to set system conditions.
TOOL Provides a data backup menu. Used to save settings and images to a computer as backup.
Save Save Used to saves data to flash memory in the Controller. If new settings have been
made, be sure to save the data before quitting.