Specifications
17
F500 Operation Manual/SECTION 1
Basic operating procedures
SECTION 1
Menu Operations
SECTION 1
Screen Displays
The Controller is operated by selecting functions from menus displayed on the
screen.Familiarize yourself with each function before operating the Controller.
*1 Mode
0.Scn 0=SET=
0.Camera image
1.
ENT:Set SFT+ESC:Edit
Scene Number
There are 32 screens. Setting 
different measurement 
conditions for each one allows 
easy switching between 
different setups.
Cursor Keys
The cursor is moved to the 
desired function by pressing 
the Cursor Keys.
A processing item is 
set for each unit.
When a measurement command is 
input, units are processed in order 
from unit 0.
Mode (*1)
The current operating mode is 
displayed.
The type of image shown on the 
screen is displayed in Monitor and 
Run Modes.
SECTION 5
System Settings  p.30
Key Operations
Displays special key combinations at the bottom of the screen 
when available.
“SFT” refers to the SHIFT Key. “SFT+ESC” indicates that the 
ESC Key should be pressed while the SHIFT Key is pressed. 
Sometimes the SFT Key display is abbreviated to just “S”.
Units
Display Contents
Setting Used to set the inspection conditions.
MON 
(Monitor)
Used to check whether inspections are being performed correctly under the set inspection 
conditions. 
The measurement results are displayed on the monitor only. The results cannot be output 
to external devices.
Measurement Performs inspection. The measurement results are output to an external device via the 
parallel interface or serial interface.
SYS (System) Used to set system conditions.
TOOL  Provides a data backup menu. Used to save settings and images to a computer as backup.
Save Save Used to saves data to flash memory in the Controller. If new settings have been 
made, be sure to save the data before quitting.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com










