Specifications

20
F500 Operation Manual/SECTION 1
Basic operating procedures
SECTION 1
Menu Operations
SECTION 1
The following type of processing is also possible by adjusting the registered order.
Example: To perform position displacement compensation separately on two
measurement objects within the same field of vision.
0.
1.
2.
3.
5.
6.
4.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.EC pos. comp
2.Fine matching
3.Reset scroll
4.EC pos. comp
5.Fine matching
6.DO judge
7.
Flowchart Image
Start
Read image from Camera.
Perform position displacement
compensation for
measurement object 1.
Inspect for defects on
measurement object 1.
Return the image to its original
position if it has been scrolled after
position displacement compensation.
Perform position displacement
compensation for
measurement object 2.
Inspect for defects on
measurement object 2.
Output measurement result
to external device.
End
Screen Image
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com