Specifications
20
F500 Operation Manual/SECTION 1
Basic operating procedures
SECTION 1
Menu Operations
SECTION 1
The following type of processing is also possible by adjusting the registered order.
Example: To perform position displacement compensation separately on two
measurement objects within the same field of vision.
0.
1.
2.
3.
5.
6.
4.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.EC pos. comp
2.Fine matching
3.Reset scroll
4.EC pos. comp
5.Fine matching
6.DO judge
7.
Flowchart Image
Start
Read image from Camera.
Perform position displacement 
compensation for 
measurement object 1.
Inspect for defects on 
measurement object 1.
Return the image to its original 
position if it has been scrolled after 
position displacement compensation.
Perform position displacement 
compensation for 
measurement object 2.
Inspect for defects on 
measurement object 2.
Output measurement result 
to external device. 
End
Screen Image
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com