Specifications

34
F500 Operation Manual/SECTION 1
Basic operating procedures
SECTION 1
Save settings to flash memory before turning the power OFF
SECTION 1
Save settings to flash memory before turning
the power OFF
Therefore, when settings have been changed, be sure to save then to flash memory before
turning OFF the power.
If the power is turned OFF without saving new settings, all of the setting changes will be lost.
Stored images cannot be saved to flash memory so all stored images will be cleared when the
power is turned OFF. If stored images are to be kept, backup the images to a personal
computer or Memory Card.
SECTION 4 Other Functions, “Backing Up Settings”
1. Display the basic screen for Monitor mode or
Run mode.
2. Place the cursor on [MON] or [RUN], and
press the ENT Key.
The mode selections will be displayed.
3. Select [SAVE].
A confirmation message will be displayed.
4. Select [Execute].
Do not turn OFF the power or input a RESET
signal while a message indicating that
processing is in progress is being displayed.
Data in memory will be destroyed, and the
Controller may not operate correctly the next
time it is started.
When saving has been completed, the screen in 1. will return.
5. Turn OFF the power supply to the Controller to shut down.
Using Scene Group Function
The scene data set to scene group 0 and system data will be saved to the Controller internal flash
memory. If this save operation is executed, the settings data for scene groups 1 to 31 will be saved
to the Memory Card mounted to drive 1.
---- ---ms
0.Scn 0 MON
---- ---ms
0.Scn 0 MON
SET
MON
RUN
SYS
TOOL
SAVE
Setting data will saved.
Execute Cancel
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com