User Manual

4.3.3. Compression Range
This control works in conjunction with the Compression Ratio.
What it does is limiting the amount of gain reduction applied, acting in practice as a Gain
Reduction Limiter. The higher the value, the less gain reduction. At 0 dB the Compression
Ratio is 1:1 (no compression).
By default, it is positioned at -100 dB (full compression). The value can be increased by any
value up to 0 dB.
4.3.4. Listen
This button enables listening to the Side-Chain signal. It is a good way to listen to the
effect induced when we apply some EQ to the detection signal, and to determine how
Compression will be applied when some frequencies are boosted or cut due to equalization
of the detection signal.
Comp VCA-65 Full
Compression Range and
Listen controls
28 Arturia - User Manual Comp VCA-65 - COMP VCA-65 CONTROL PANEL