User`s manual

24 ARTURIA MiniLab USER’S MANUAL
4.4.2.3 Settings for the Pitch Strip
Settings that are available for the pitch strip are:
Pitch Bend
Standard: After the pitch strip is released the value will return
to zero (center)
Hold: When the pitch strip is released the most recent value will
be retained until that strip is touched again.
4.4.2.4 Settings for the Modulation Strip
Settings that are available for the modulation strip are:
Continuous
Set the CC number and the Min/Max range as desired and the
Mod strip will transmit that MIDI data when pressed.
NRPN/RPN
NRPN: Non-Registered Parameter Numbers are used to access
many more parameters than the unassigned MIDI CC numbers
could represent. Use the LSB / MSB fields to specify the
controller number. Min/Max are ignored in this case.
Please refer to the documentation of the receiving device for specific settings.
RPN: Registered Parameter Numbers control specific parameters
such as Pitch Bend range and Tuning. Use the LSB / MSB fields to
specify the parameter number. Min/Max are ignored in this case.
Aftertouch
Standard: After the modulation strip is released the aftertouch
value will return to zero
Hold: When the modulation strip is released the most recent
aftertouch value will be retained until that strip is touched again.
Min / LSB
and
Max / MSB
Depending on the settings of the other parameters, these fields
will serve one of the following functions:
Define a minimum / maximum range for a standard MIDI
Continuous Controller setting (switch-type or variable).
MSB/LSB are not used in this case.
NRPN/RPN: specify the Most Significant Byte (MSB) or
Least Significant Byte (LSB) for the controller number.
Min/Max are not used in this case.