User`s manual
ARTURIA – MOOG MODULAR V 2.6 – USER’S MANUAL  95 
It is possible to force the sequencer to initialize itself on a particular step, either by clicking on 
the “Forcing” button of the desired step, or through a signal in the associated input trigger. 
Every  time  the  sequencer  comes  to  a  step,  the  corresponding  trigger  output  is  activated, 
allowing the start-up of certain envelopes. 
It is possible to remain on a particular step by modifying the “Hold” display. In this case, we 
need a certain number of clock impulses from the sequencer (or from the trigger input) equal 
to the number indicated to go to the next step. 
The  rotating  selector indicates  the  next  step.  It  possesses  10  positions,  the first 8  represent 
the next steps, the ninth is a random selection, and the last is the generator stop. 
When  this  last  position  is  chosen  on  a  step,  the  sequencer  clock  is  stopped,  the  manager  is 
reset on the first step and the outputs set to zero. 
At every change of step, a general trigger signal from the sequencer is activated. This output 
will  be  activated  at  every  clock  impulse  if  the  “repetition”  interrupter  is  active.  In  the  same 
manner, there is no activity from this signal if the “link” interrupter is inactive. 
Sequencer outputs 
Smooth 1  Sets smooth for output 1 
Smooth 2  Sets smooth for output 2 
Smooth 3  Sets smooth for output 3 
Smooth 4  Sets smooth for output 4 
On Line1  Forcing of the selection from output 4 to output 1 
Forcing Trigger Input 1  Forcing trigger input of the selection from output 4 to output 1 
On Line2  Forcing of the selection from output 4 to output 2 
Forcing Trigger Input2  Forcing trigger input of the selection from output 4 to output 2 
On Line3  Forcing of the selection from output 4 to output 3 
Forcing Trigger Input3  Forcing trigger input of the selection from output 4 to output 3 
Mode Output4  Choice of progression mode of output 4 
The  control  section  of the  sequencer outputs allows  the management  of  four outputs  in 
function with the current step. The first outputs take their values from the values specified by 
the  rotating  buttons  of  the  current  step,  eventually  with  a  smooth  that  can  be  set  with  the 
“smooth”. 
Smooth1 
Smooth2 
Smooth3 
Smooth4 
On Line 1 
Forcing Trigger Input 1 
On Line 2 
Forcing Trigger Input 2 
On Line 3 
Forcing Trigger Input 3 
Mode Output 4 










