5400R zl2 Switch Series

QuickSpecs
Aruba 5400R zl2 Switch Series
Technical Specifications
Page
39
v3 40G module
Dual ARM Coretex A9 @ 1 GHz; Packet buffer size: 13.5 MB internal
Management Module
Freescale P2020 dual core @ 1.2 GHz, 16 MB flash, 1 GB SD Card, 4 GB
DDR3 SODIMM
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
1000 Mb Latency
< 2.8 µs (FIFO 64-byte packets)
10 Gbps Latency
< 1.8
µ
s (FIFO 64-byte packets)
40 Gbps Latency
< 1.5 µs (FIFO 64-byte packets)
Throughput
up to 571.4 Mpps
Routing/Switching
capacity
960 Gbps
Switch fabric speed
1015 Gbps
Routing table size
10000 entries (IPv4), 5000 entries (IPv6)
MAC address table size
64000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C); 0°C to 40°C with J8177C transceiver installed,
0°C to 35°C with FIPS Opacity Shield installed
Operating relative
humidity
15% to 95% @ 113°F (45°C), noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
15% to 95% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft (3 km)
Acoustic
Power: 44 dB, Pressure: 31.7 dB ISO 7779, ISO 9296
Electrical characteristics
Frequency
50/60 Hz
80plus.org Certification
Gold
Description
Does not come with power supply. Two open power supply slots are
available; three different power supplies are available. See power supply
products for additional specifications
Maximum heat
dissipation
2450 BTU/hr (2584.75 kJ/hr), (max. non-PoE); 3700 BTU/hr (3903 kJ/hr)
(max. using PoE)
Voltage
110 - 127 / 200 - 240 VAC, rated
Idle power
215 W
NOTES
Idle power is the actual power consumption of the device with no ports
connected.
Heat dissipation does not include heat dissipated by the PoE-powered
devices themselves.
Safety
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions
FCC part 15 Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD; HPE ENV. 765.002
Radiated
IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC, 1kV signal, 0.5 kV DCIEC 61000-4-6; 3
Vrms
Conducted
IEC 61000-4-6; 3 Vrms