Repair Manual, Parts List, Diagrams and Assembling Charts
23602 /7
9. Shutter speed adjustment:
Testers:Light value correction unit. TSST-3A. T adjuster (or battery), ESST-1A, digital counter,
diaphragm setting ring (KA-00-lA), 23600K-A400-A.
Procedure:
(a) Auto speed adjustable resistor R7
(1X, ASA100, 2.8V)
EV12 — 1/60 sec
EV16 — 1/1000
EV16(2X) — 1/500
EV8 — 1/4
EV4 — 1
(b) Meter level — R10
EVI6 — 1/1000sec
(c) Meter sensitivity — R9
EV8 — 1/4
(d) Manual shutter speed — Rl2
EVI2 — 1/60
(check all shutter speeds to see Rotary SW contact effects)
(e) Battery Checker
2.1V OFF
2.4V ON
(No adjustment is allowed because no tester is supplied).
Fig. 16
Fig. 17