User`s manual

Installation Guide
IntraStack
6008FXE
Overview
The Asanté IntraStack 6008FXE is an 8-port fiber expansion unit for the IntraStack
6014DSB Ethernet switch.
The IntraStack 6008FXE provides expansion to the 6014DSB with eight 100Mbps fiber-
optic links. Each port is capable of running at a maximum bandwidth of 200Mbps in full
duplex mode.
Important: The IntraStack 6008FXE is not a stand-alone switch; it must be
connected to an IntraStack 6014DSB.
This guide provides instructions for mounting, installing, and connecting your IntraStack
6008FXE. For information on managing the IntraStack 6008FXE or configuring one of its
ports, refer to the IntraStack 6014DSB User's Manual.
Important: Do not install the 1.25-inch GoldCard connector included in
this package into an IntraStack 6014DSB (base unit).
Additional materials required:
Network cables — 62.5/125 micron graded-index multimode fiber-optic cable with
an SC connector.
Phillips screwdriver — for rack-mounting the IntraStack 6008FXE.
Package Contents
(3) Stack-mounting brackets
(2) Rack-mounting brackets
(14)Standard Phillips screws (10/32 x .5")
(1) Installation Guide (this card)
(1) Registration card
The IntraStack 6008FXE is shipped with the following items:
(1) IntraStack 6008FXE Expansion Unit
(1) GoldCard™ connector (1.25-inch)
(1) Power cord
(2) Stack-mounting pins
Default Port Setting
The IntraStack 6008FXE is shipped with the following default port configuration setting:
Full Duplex Mode on all ports
Installing on Top of the 6014DSB Base Unit
If you are installing the IntraStack 6008FXE directly on top of the 6014DSB:
Use the 2.7-inch GoldCard connector included with the IntraStack 6014DS
B
Installing on Top of another Expansion Unit
If you are installing the 6008FXE on top of another expansion unit:
Use the 1.25-inch GoldCard connector included in this package.
The IntraStack's stackable design uses Asanté's GoldCard connector technology to
expand the switching system via a 2Gbps PCI backplane connector.
Up to two expansion units can be added to the top of an IntraStack 6014DSB.
Important: IntraStack expansion units, such as the 6008FXE, must be installed
on top of an IntraStack 6014DSB base unit.
Depending upon the placement of the IntraStack 6008FXE in the IntraStack
switching system — either on top of the 6014DSB or on top of another expan-
sion unit— you may need to use the 2.7-inch GoldCard connector included with
the IntraStack 6014DSB or the 1.25-inch GoldCard connector included with the
6008FXE expansion unit.
2 Determine GoldCard Connector
IntraStack 6014DSB
1.25-inch GoldCard connector
included with the
IntraStack 6008FXE
2.7-inch GoldCard connector
included with the
IntraStack 6014DSB
If your IntraStack 6014DSB is installed in an equipment rack, the IntraStack 6008FXE
must be prepared for rack mounting by installing the two rack-mounting brackets
(included in this package) on the 6008FXE.
For example, if you are installing the 6008FXE onto an IntraStack 6014DSB base unit
that is installed in an equipment rack, mount the two rack-mounting brackets on the
IntraStack 6008FXE, then install the 6008FXE onto the 6014DSB (while the 6014DSB
remains in the equipment rack).
If your IntraStack switching system is not installed in an equipment rack, make sure
the units are placed on a stable, horizontal surface with support capabilities of 21.5
pounds (9.7 kilograms) (31 pounds [14 kilograms] for a full stack of 3 units).
Install Rack-Mounting Brackets
To install the two rack-mounting brackets on the IntraStack 6008FXE:
1. Place the IntraStack 6008FXE on a flat, stable surface.
2. Locate a rack-mounting bracket (supplied) and place it over the mounting
holes on one side of the unit, as shown below.
3. Insert four screws (supplied) into the holes and tighten with a Phillips screw-
driver.
4. Repeat the two previous steps for the unit's other side.
The IntraStack 6008FXE is ready to be installed onto an IntraStack 6014DSB.
5. Proceed to Step 2, "Determine Placement in the IntraStack System" to
continue with the installation.
1 Prepare for Rack Mounting
Expansion Slot
remove protective covering;
do not remove the two EMI gask
e
strips (these strips are parallel wi
the expansion slot)
The IntraStack 6008FXE can be installed onto an IntraStack 6014DSB (or onto anoth
expansion unit) while the 6014DSB is installed in an equipment rack.
To install the IntraStack 6008FXE :
Note: These instructions pertain to installing the 6008FXE onto an IntraStack 6014D
or onto another expansion unit; however, as an example, the IntraStack 6008FXE will
installed directly on top of an IntraStack 6014DSB in these instructions.
1. Make sure all IntraStack units are powered off.
2. Make sure the IntraStack 6014DSB is on a flat, stable surface or is properly
installed in an equipment rack.
3. Remove the protective covering from the top of the IntraStack 6014DSB to
expose its expansion slot.
3 Install the IntraStack 6008FXE