Product Overview

Pipe
Size
in
Orifice
Size
in (mm)
Flow
Cv (Kv)
Operating Pressure Differential, psi (bar)
Maximum
Fluid Temp. ˚F (˚C)
Catalog
Number
Watt Rating/
Insulation Class
Min.
Press
Max. AC @ 131 F (55 C) Max. DC @ 104 F (40 C)
Air-
Inert Gas
Water
Lt. Oil @
300 ssu
Air-
Inert Gas
Water
Lt. Oil @
300 ssu
AC DC AC DC
General Service - Normally Closed, Direct Acting
1/8 1/8 (3.2) 0.35 (0.30) 0 185 (13) 180 (12) 120 (8) 130 (9) 110 (8) 95 (7) 180 (82) 180 (82) 8262H002LF 6.1/F 10.6/H
1/4 3/32 (2.4) 0.21 (0.18) 0 370 (26) 330 (23) 160 (11) 235 (16) 160 (11) 160 (11) 180 (82) 180 (82) 8262H020LF 6.1/F 10.6/H
1/4 1/8 (3.2) 0.35 (0.30) 0 185 (13) 180 (12) 90 (6) 130 (9) 110 (8) 90 (6) 180 (82) 180 (82) 8262H022LF 6.1/F 10.6/H
1/4 7/32 (5.6) 0.73 (0.63) 0 55 (4) 54 (4) 40 (3) 38 (3) 33 (2) 31 (2) 180 (82) 180 (82) 8262H013LF 6.1/F 10.6/H
3/8 5/32 (4.0) 0.52 (0.45) 0 210 (14) 185 (13) 100 (7) 65 (4) 63 (4) 50 (3) 180 (82) 180 (82) 8263H200LF 10.1/F 11.6/H
General Service - Normally Closed, Pilot Operated
1/2 5/8 (16) 4 (3.4) 5 (0.3) 200 (14) 150 (10) 135 (9) 125 (9) 100 (7) 100 (7) 180 (82) 150 (65) 8210G002LF 6.1/F 11.6/F
1/2 5/8 (16) 4 (3.4) 0 150 (10) 150 (10) - 40 (3) 40 (3) - 180 (82) 150 (65) 8210G094LF 10.1/F 11.6/F
3/4 3/4 (19) 5 (4.3) 5 (0.3) 125 (9) 125 (9) 125 (9) 100 (7) 90 (6) 75 (5) 180 (82) 150 (65) 8210G009LF 6.1/F 11.6/F
3/4 3/4 (19) 5 (4.3) 0 150 (10) 150 (10) - 40 (3) 40 (3) - 180 (82) 150 (65) 8210G095LF 10.1/F 11.6/F
1 1 (25) 13 (11) 5 (0.3) 150 (10) 150 (10) 100 (7) 125 (9) 125 (9) 125 (9) 180 (82) 150 (65) 8210G004LF 6.1/F 11.6/F
APPLICATIONS
FEATURES & BENEFITS
1/8" to 1" NPT
www.asco.com
Lead-Free
Brass
1
SPECIFICATIONS
Lead-free water handling requiring
Safe Drinking Water Act (SDWA)
Section 1417 compliance:
Equipment in contact with
drinking water
Dishwashing
General plumbing
Water automation
09/16 - V7726
• Valves comply with Safe Drinking Water Act (SDWA) Section 1417
Lead Free requirements
•Contains less than 0.25% lead in wetted surface areas of the valves
•Simplifies the design of equipment meeting SDWA 1417
•Streamlines SDWA equipment installation and repair
• Widest range of pressures, sizes and flows to meet application needs
• With pipe sizes ranging from 1/8” to 1”, ASCO offers a lead-free brass
1
valve for virtually every application
• Zero Differential Pressure Operation
• Valves requiring zero differential pressure are available in sizes up to ¾
• Rugged Design
• Utilizes the same design and construction as the trusted 8210, 8262, and 8263 valve series
• Lead-free brass
1
valves carry the same UL and CSA approvals as standard brass valves
• Simplified Supply Chain
• Popular constructions are available through the ASCO Express shipping program
which allows for fast part replacement and greater availability
• Lead-free valves offer the same water, air, and oil pressure ratings as regular brass ASCO valves,
allowing for stock consolidation—one valve controls the flow of all fluids while meeting SDWA lead-free requirements
2-Way Valves with SDWA Compliance
1
The term “Lead-Free” for brass materials is defined by SDWA 1417 as having a maximum
weighted average lead content of 0.25% on the wetted surface area.

Summary of content (1 pages)