Submittal Sheet

2/2
SERIES
8262
8263
% ^ # )
Features
• Welded core tube provides higher pressure ratings
Reliable, proven design with high flows
Small poppet valves for tight shutoff
Wide range of elastomers for specialty service applications
Mountable in any position
• Tapped mounting holes in body standard
Direct Acting, Normally Closed
General Service Solenoid Valves
Brass or Stainless Steel Bodies
1/8" to 3/8" NPT
NC
Solenoid Enclosures
Nominal Ambient Temp. Ranges
The nominal limitation of 32°F (0°C) is advisable for any
valve that might contain moisture (water vapor).
AC: -13˚F to 131˚F (-25˚C to 55˚C)
DC: -13˚F to 104˚F (-25˚C to 40˚C)
-13˚F to 131˚F (-25˚C to 55˚C)
Note: Max ambient for explosionproof (EF) is 125˚F
(52˚C) for AC, 131˚F (55˚C) for DC.
Optional: For AC, the max. ambient temperature is
140˚F (60˚C) with Class H coil (with or without prefix EF)
Refer to Engineering Section for details.
Approvals
CSA certified. UL listed, as indicated. Safety Shutoff
Valves FM approved. Meets applicable CE directives.
Refer to Engineering Section for details.
Construction
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X.
Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.
(To order, add prefix “EF” to catalog number)
See Optional Features Section for other available options.
4
2-WAY
31
Valve Parts in Contact with Fluids
Body Brass Cast 304 Stainless Steel
Seals and Discs NBR or Cast UR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs 302 Stainless Steel
Shading Coil Copper Silver
Watt Rating and
Power Consumption Spare Coil Part No.
DC
Watts
AC General Purpose Explosionproof
Watts
VA
Holding VA Inrush AC DC AC DC
10.6 6.1* 16 30 238210 238510 238214 238514
18.6 9.1* 20 45 238210 238510 238214 238514
11.6 10.1 25 50 238610 238910 238614 238914
22.6 17.1 40 70 238610 238910 238614 238914
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).
6, 12, 24, 120, 240 volts DC. Must be specified when ordering.
Other voltages available when required.
*On 50 hertz service, the rating for the 6.1/F solenoid is 8.1 watts, and
the rating for the 9.1/F solenoid is 11.1 watts.
Electrical
Options
Mounting bracket (suffix MB)
Quarter-turn manual operator with screw slot (suffix MS)
Panel mount (prefix GP for conduit;
consult ASCO for other electrical connections
)
Vacuum service (suffix VVM, VVH;
see Vacuum Section for more details.
)
Oxygen service (suffix N)
Silicone Free (suffix SF)
Elastomers: FKM (suffix V), Ethylene Propylene (suffix E),
CR (suffix J), Teflon (suffix T), Low Temp NBR (suffix A)
Note: For suffix A, Fluid temp. range -40˚F to 167˚F only for valves with 10.1,
17.1, 11.6, and 22.6 watt coils.
Refer to Engineering Section for fluid and temperature compatibility.
8262_8263_HSeries_GP_R5