User's Manual
Table Of Contents
- 1 Introduction
- 2 Description
- 3 Safety Instructions
- 4 IP Security
- 5 Installation of the Base Station
- 5.1 Base Station Cabling
- 5.2 Install the Base Station
- 5.2.1 Fix the Mounting Bracket to a Wall
- 5.2.2 Fix the Mounting Bracket to a Ceiling
- 5.2.3 Fix the Mounting Bracket to a Pole or Beam
- 5.2.4 Use the Cable Ducts for IPBS1
- 5.2.5 Connect External Antennas (only IPBS2 and DB1)
- 5.2.6 Secure the Cable
- 5.2.7 Pinning
- 5.2.8 Connect the Base Station Cables
- 5.2.9 Mount the Base Station
- 5.3 Power the Base Station
- 6 Installation of the IPBL
- 7 Configuration
- 7.1 Requirements
- 7.2 Access the GUI
- 7.3 GUI Web Access
- 7.4 Configure the Mobility Master
- 7.5 Configure the Standby Mobility Master
- 7.6 Configure the Pari Master
- 7.7 Configure the Standby Pari Master
- 7.8 Configure the Master
- 7.9 Configure the Standby Master
- 7.10 Plug and Play Configuration
- 7.11 Configure the Radio
- 7.12 Configure Deployment
- 7.13 Add Users
- 8 Operation
- 8.1 General
- 8.1.1 Name the IPBS/IPBL
- 8.1.2 Change User Name and Password
- 8.1.3 Centralized Management of Administrator/Auditor Accounts Using Kerberos
- 8.1.4 Configure Automatic Firmware Update
- 8.1.5 Configure the NTP Settings
- 8.1.6 Configure Logging
- 8.1.7 Configure the HTTP settings
- 8.1.8 Configure the HTTP Client settings
- 8.1.9 SNMP
- 8.1.10 Certificates
- 8.1.11 License
- 8.2 LAN
- 8.3 IP
- 8.4 LDAP
- 8.5 DECT
- 8.5.1 Change System Name and Password
- 8.5.2 Set Subscription Method
- 8.5.3 Configure Authentication Code
- 8.5.4 Select Tones
- 8.5.5 Set Default Language
- 8.5.6 Set Frequency Band
- 8.5.7 Enable Carriers
- 8.5.8 Local R-Key Handling
- 8.5.9 No Transfer on Hangup
- 8.5.10 Configure Coder
- 8.5.11 Secure RTP
- 8.5.12 Configure Supplementary Services
- 8.5.13 Select Mode
- 8.5.14 Set Master Id
- 8.5.15 Enable PARI Function
- 8.5.16 Configure Gatekeeper
- 8.5.17 Registration for Anonymous Devices
- 8.5.18 Select Mobility Master Mode
- 8.5.19 Connect Mobilty Master to other Mobility Master(s)
- 8.5.20 Disconnect Mobilty Master from other Mobility Master(s)
- 8.5.21 Connect Master to a Mobility Master
- 8.5.22 Enable the Radio
- 8.5.23 Enter IP Address to the PARI Master and the Standby PARI Master
- 8.5.24 Multiple Radio Configuration
- 8.5.25 PARI
- 8.5.26 SARI
- 8.5.27 Configure Air Synchronization
- 8.6 VoIP
- 8.7 UNITE
- 8.8 Import and Export a Central Phonebook
- 8.9 Users
- 8.10 Device Overview
- 8.11 DECT Sync
- 8.12 Traffic
- 8.13 Gateway
- 8.14 Backup
- 8.15 Software Upgrade
- 8.15.1 Before Upgrading
- 8.15.2 Upgrading Sequence
- 8.15.3 IPBS/IPBL Upgrade
- 8.15.4 Configuration After Updating the Firmware From Software Version 2.x.x to Later
- 8.15.5 Configuration After Updating the Firmware From Software Version 3.x.x to Later
- 8.15.6 System Upgrade from Software Version 4.x.x to 5.0.x
- 8.16 System Downgrade from software version 5.0.x to 2.x.x, from 4.x.x to 2.x.x and from 3.x.x to 2.x.x
- 8.17 System Downgrade from software version 5.0.x to 3.x.x and 4.x.x to 3.x.x
- 8.18 Update
- 8.19 System Upgrade in System with Mobility Masters
- 8.20 Replacing Master Hardware in Multiple Master System
- 8.21 Diagnostics
- 8.22 Reset
- 8.23 Reset Using the Reset Button
- 8.1 General
- 9 Commissioning
- 10 Troubleshooting
- 11 Related Documents
- Document History
- Appendix A: How to Use the Update Server
- Appendix B: RFP Power Consumption
- Appendix C: Local R-Key Handling
- Appendix D: Database Maintenance
- Appendix E: Load Balancing
- Appendix F: Update Script for Configuration of Kerberos Clients
- Appendix G: Install Certificate in the Web Browser
TD 92579EN
15 February 2012 / Ver. H
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 5.0.x)
55
NOTE: For coverage test of air sync, two IPBSs must be configured, one as Sync Master
and one as Sync Slave.
Each configuration step is briefly described in the step list below. For more detailed
information see the corresponding subsection in 8 Operation on page 60.
1 Determine the IP address and access the GUI, see 7.2 Access the GUI on page 42.
2 Change the default password, see 7.2.2 Change the Default Password on page 44.
3 Set a static IP address and set DHCP to off, see 8.2.2 Set a Static IP Address on page
80.
4 Set the mode to Master, see 8.5.13 Select Mode on page 94.
5 Perform a reset to restart the IPBS/IPBL in Master mode, see 8.22 Reset on page
138.
6 Select system name and password, see 8.5.1 Change System Name and Password
on page 89.
7 Set subscription method, see 8.5.2 Set Subscription Method on page 89.
8 Configure authentication code, see 8.5.3 Configure Authentication Code on page
90.
9 Select tones, see 8.5.4 Select Tones on page 90.
10 Set default language, see 8.5.5 Set Default Language on page 90.
11 Set frequency band, see 8.5.6 Set Frequency Band on page 90.
12 Enable carriers, see 8.5.7 Enable Carriers on page 91.
13 Set Master Id, see 8.5.14 Set Master Id on page 94.
14 Enable Pari function, see 8.5.15 Enable PARI Function on page 94.
15 Assign PARI, see 8.5.25 PARI on page 99. Note: If two IPBss are configured for
coverage test of air sync, both IPBS must have the same system ID.
16 Enter SARI, see 8.5.26 SARI on page 100.
17 Reset in order to make the configuration changes take effect, see 8.22 Reset on
page 138.
18 For coverage test of speech sync, register one handset in the IPBS configured as
Sync Master, see
7.13 Add Users on page 55.
19 Set the mode to Deployment, see 8.5.13 Select Mode on page 94.
7.13 Add Users
This section describes how to add users to the IP-DECT system. The IPEI, which is the
unique identification number of the handset, can be registered in three ways:
• Anonymous Registration can be used in en existing IP-DECT system. Instead of the
administrator collects all the handset, the user of the handset does the registration.
The IPEI is automatically associated to the user, see
7.13.1 Anonymous Registration on
page 56.
• Individual Registration can be used if a few new handsets shall be added to the IP-
DECT System. The IPEI is entered manually, see
7.13.2 Individual Registration on page
57.
• Easy Registration can be used if many users shall be added to the IP-DECT System. The
IPEI is entered with for example a barcode reader to a csv file, see
7.13.3 Easy
Registration on page 58.