User's Manual

Table Of Contents
TD 92579EN
15 October 2014 / Ver. M
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
116
4.26.5 Performance
It is possible to check different performance parameters. For a description of the
p
arameters, see the table below.
Typ e The status of the fault. It has four possible states:
Alarm - Alarms displayed in red are
a
ctive alarms
Alarm cleared - The alarm is already
clear
ed
Alarm timeout - The alarm
e
xceeded the timeout period
Error - Refers to faults that are not
a
ctive for a specific time.
Code A unique number that identifies the alarm.
Click the
code to get more detailed information about the
alarm. For a list of possible codes and their
descriptions, see 6.2 Fault Code Descriptions on
page 123.
Severity It has three possible states:
Critical - Immediate action is
r
equired. It is displayed, for
example, if a managed object goes
out of service.
Major - Urgent action is required. It
is
displayed, for example, if the
capability of the managed object is
severely degraded.
Indeterminate - Level of severity
can
not be determined
Remote The IP Address of the object that r
eported the alarm.
Click the IP address to access the object.
Source The software module that reported the alarm.
T
ogether with the code it uniquely identifies an
alarm.
Description A textual description of the alarm.
Parameter Description
CPU Shows CPU utilization. To have a 100% utilization
f
or a longer time is not good but occational peaks
are acceptable. Reason for high utilization may be
caused by running SRTP. Another reason may be
that there are a lot of users registered on the Master.
CPU-R Shows utilization of CPU resources allocated by
dif
ferent tasks. If the CPU resources are fully utilized
it will prevent connection of more calls. One solution
in that case can be to install an additional Base
Station in the same coverage area.