User's Manual
Table Of Contents
- 1 Introduction
- 2 IP Security
- 3 Configuration
- 3.1 Requirements
- 3.2 Access the GUI
- 3.3 GUI Web Access
- 3.4 Configure the Mobility Master
- 3.5 Configure the Standby Mobility Master
- 3.6 Configure the Pari Master
- 3.7 Configure the Standby Pari Master
- 3.8 Configure the Master
- 3.9 Configure the Standby Master
- 3.10 Plug and Play Configuration
- 3.11 Configure the Radio
- 3.12 Configure Deployment
- 3.13 Add Users
- 4 Operation
- 4.1.1 Name the IPBS and IPBL
- 4.1.2 Change User Name and Password
- 4.1.3 Centralized Management of Administrator and Auditor Accounts Using Kerberos
- 4.1.4 Configure the NTP Settings
- 4.1.5 Certificates
- 4.1.6 License
- 4.2.1 Set DHCP Mode
- 4.2.2 Set a Static IP Address
- 4.2.3 Dynamic IP address via DHCP
- 4.2.4 Link
- 4.2.5 Configure VLAN
- 4.2.6 View LAN Statistics
- 4.2.7 Enable RSTP (only for IPBL)
- 4.2.8 Deactivate LAN Port (only for IPBL)
- 4.3.1 Configure IP Settings
- 4.3.2 Routing
- 4.4.1 Configure LDAP Server
- 4.4.2 Check LDAP Server Status
- 4.4.3 Configure LDAP Replicator
- 4.4.4 Check LDAP Replicator Status
- 4.4.5 Expert tool
- 4.5.1 Change System Name and Password
- 4.5.2 Set Subscription Method
- 4.5.3 Configure Authentication Code
- 4.5.4 Select Tones
- 4.5.5 Set Default Language
- 4.5.6 Set Frequency Band
- 4.5.7 Enable Carriers
- 4.5.8 Local R-Key Handling
- 4.5.9 No Transfer on Hangup
- 4.5.10 No On-Hold Display
- 4.5.11 Display Original Called
- 4.5.12 Early Encryption
- 4.5.13 Configure Coder
- 4.5.14 Secure RTP
- 4.5.15 Configure Supplementary Services
- 4.5.16 Select Mode
- 4.5.17 Set Master Id
- 4.5.18 Enable PARI Function
- 4.5.19 Set Region Code
- 4.5.20 Configure Gatekeeper
- 4.5.21 Registration for Anonymous Devices
- 4.5.22 Conferencing Unit
- 4.5.23 Select Crypto Master Mode
- 4.5.24 Select Mobility Master Mode
- 4.5.25 Connect Mobility Master to other Mobility Master(s)
- 4.5.26 Disconnect Mobility Master from other Mobility Master(s)
- 4.5.27 Connect Mobility Master to a Crypto Master
- 4.5.28 Connect Master to a Mobility Master
- 4.5.29 Enable the Radio
- 4.5.30 Enter IP Address to the PARI Master and the Standby PARI Master
- 4.5.31 Multiple Radio Configuration
- 4.5.32 PARI
- 4.5.33 SARI
- 4.5.34 Configure Air Synchronization
- 4.6.1 Add instance id to the user registration with the IP-PBX
- 4.6.2 IP-PBX supports redirection of registration when registered to alternative proxy
- 4.6.3 Use local contact port as source port for TCP and TLS connections
- 4.6.4 Session Timer (initial value)
- 4.7.1 Configure Messaging
- 4.7.2 Device Management
- 4.7.3 Service Discovery
- 4.7.4 Send Status Log
- 4.7.5 Module Fault List
- 4.8.1 Configure Automatic Firmware Update
- 4.8.2 Configure Logging
- 4.8.3 Configure the HTTP settings
- 4.8.4 Configure the HTTP Client settings
- 4.8.5 SNMP
- 4.8.6 Phonebook
- 4.8.7 Configure IP-DECT to Connect to a Presence System Using ICP
- 4.9.1 Show all Registered Users in the IP-DECT System
- 4.9.2 Search for User Information
- 4.9.3 Add a User
- 4.9.4 Add a User Administrator
- 4.9.5 Export the Users to a csv file
- 4.9.6 Show Anonymous
- 4.10.1 Radios
- 4.10.2 RFPs
- 4.10.3 Sync Ring
- 4.10.4 Sync Ports
- 4.10.5 Air Sync
- 4.10.6 Sync Lost Counter in IPBS
- 4.11.1 Air Sync Overview
- 4.11.2 Disturbances
- 4.11.3 Status
- 4.12.1 Display All Ongoing Calls in the System
- 4.12.2 Display Calls
- 4.12.3 Handover
- 4.13.1 General
- 4.13.2 Interfaces
- 4.13.3 SIP Interfaces
- 4.13.4 Gatekeeper Interfaces
- 4.13.5 Routes – Configuration
- 4.13.6 Show Active Calls
- 4.15.1 Before Upgrading
- 4.15.2 Upgrading Sequence
- 4.15.3 Software Upgrade from 2.X.X
- 4.15.4 Software Upgrade
- 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later
- 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later
- 4.21.1 Update Configuration
- 4.21.2 Update Firmware
- 4.21.3 Update the Boot File
- 4.21.4 Update the RFPs
- 4.26.1 Logging
- 4.26.2 Tracing
- 4.26.3 Alarms
- 4.26.4 Events
- 4.26.5 Performance
- 4.26.6 Config Show
- 4.26.7 Ping
- 4.26.8 Traceroute
- 4.26.9 Environment
- 4.26.10 RFP Scan
- 4.26.11 Service Report
- 4.27.1 Idle Reset
- 4.27.2 Immediate Reset
- 4.27.3 TFTP Mode
- 4.27.4 Boot
- 5 Commissioning
- 6 Troubleshooting
- 7 Related Documents
- Document History
- Appendix A: How to Configure and Use the Update Server
- Appendix B: Local R-Key Handling
- Appendix C: Database Maintenance
- Appendix D: Load Balancing
- Appendix E: Update Script for Configuration of Kerberos Clients
- Appendix F: Install Certificate in the Web Browser
- Appendix G: Used IP Ports
- Appendix H: Configure DHCP Options
TD 92579EN
15 October 2014 / Ver. M
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
22
The IPEI is automatically associated to the user, see 3.13.1 Anonymous Registration on
page 22.
• Individual Registration can be used if a few
new handsets shall be added to the IP-
DECT System. The IPEI is entered manually, see 3.13.2 Individual Registration on page
23.
• Easy Registration can be used if many users sh
all be ad
ded to the IP-DECT System. The
IPEI is entered with for example a barcode reader to a csv file, see 3.13.3 Easy
Registration on page 25.
Note: Display Na
me
is only used during Active Directory (AD) replication, see Attribute
Mappings on page 50.
3.13.1 Anonymous Registration
Anonymous Registration is done in two steps. First, the user is registered in the IP-DECT
System. Second, the handset is assigned to the user fr
om the handset.
Add users in the IP-DECT System
1 Under Adm
i
nistration, select "Users".
2 Click "New".
3 Enter the following information in the corr
esponding text fields, leave the IPEI / IPDI
text field empty, do not remove the automatically generated Auth. Code:
Field name Description Max. characters
Long Name Mandatory, the name of the user, need to be
u
n
ique throughout the system.
30
Display Name Optional and only available when using the
Ascom Vo
IP Gateway, the calling or called
party name will be shown in the handset
display (depending on whose handset).
30
Name Optional, the user name. 30
Number Mandatory, the phone number extension,
n
e
ed to be unique throughout the system.
30
Auth Name
(SIP)
Auth name is the Authentication name used
in SIP a
uthentication. If it is not set the
number will be used as authentication name.
If SIP authentication is used or not is decided
by
th
e configuration in the IP-PBX.
60
Password Optional, is used for registration towards the
gatek
eeper. However, in a system with many
users where the same password shall be
used for all users, instead of setting the
password here, it is possible to use the
system password for registration towards the
gatekeeper. To enable registration with
system password, see 4.5.20 Configure
Gatekeeper on page 63.
30
Idle Display Optional, will be shown in the handset
display whe
n
the handset is idle.
47
4 Click "OK".
5 Repeat step 2 to 4 for all users.