User's Manual

Table Of Contents
TD 92579EN
15 October 2014 / Ver. M
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
62
Figure 5. Supplementary services
4.5.16 Select Mode
1 Select DECT > Master.
2 Note:
The Master can be set to be inactive or active or for redundancy purposes,
the Master can be set to act in two other ways: As Standby or Mirror.
Select in the Mode dr
op-down list one of the following:
"Off", if this IPBS/IPBL is not a Master.
"Active", if this IPBS/IPBL is the Master.
"Standby", if this IPBS/IPBL is the
Standby Master.
"Deployment" is used for coverage test
only. The speech from the handset is
looped back to the handset.
"Mirror", if this IPBS/IPBL is the Mirror.
For information about Mirror devices, see
the system description for IP-DECT.
3 If you have selected the "Standby" mode ente
r the primary Master IP address in its
text field.
4 If you have selected the "Mir
ror" mode enter the IP address to the other Mirror
Master in the Mirror Master IP address text field.
For the Master that initially sha
ll be the active Mirror: Click on the text link "Activate
mirror". Any user and handset data in the inactive Mirror will be replaced with the
user and handset data stored in the active Mirror.
To switch the active role between the Mirror Masters,
click on the text link "Switch
active mirror". Note: This should be done within a maintenance window as all
active calls will be lost.
5 Click "OK".
6 Reset in order to make the changes take effect, see 4.27 Reset on page 118.