User's Manual
Table Of Contents
- 1 Introduction
- 2 IP Security
- 3 Configuration
- 3.1 Requirements
- 3.2 Access the GUI
- 3.3 GUI Web Access
- 3.4 Configure the Mobility Master
- 3.5 Configure the Standby Mobility Master
- 3.6 Configure the Pari Master
- 3.7 Configure the Standby Pari Master
- 3.8 Configure the Master
- 3.9 Configure the Standby Master
- 3.10 Plug and Play Configuration
- 3.11 Configure the Radio
- 3.12 Configure Deployment
- 3.13 Add Users
- 4 Operation
- 4.1.1 Name the IPBS and IPBL
- 4.1.2 Change User Name and Password
- 4.1.3 Centralized Management of Administrator and Auditor Accounts Using Kerberos
- 4.1.4 Configure the NTP Settings
- 4.1.5 Certificates
- 4.1.6 License
- 4.2.1 Set DHCP Mode
- 4.2.2 Set a Static IP Address
- 4.2.3 Dynamic IP address via DHCP
- 4.2.4 Link
- 4.2.5 Configure VLAN
- 4.2.6 View LAN Statistics
- 4.2.7 Enable RSTP (only for IPBL)
- 4.2.8 Deactivate LAN Port (only for IPBL)
- 4.3.1 Configure IP Settings
- 4.3.2 Routing
- 4.4.1 Configure LDAP Server
- 4.4.2 Check LDAP Server Status
- 4.4.3 Configure LDAP Replicator
- 4.4.4 Check LDAP Replicator Status
- 4.4.5 Expert tool
- 4.5.1 Change System Name and Password
- 4.5.2 Set Subscription Method
- 4.5.3 Configure Authentication Code
- 4.5.4 Select Tones
- 4.5.5 Set Default Language
- 4.5.6 Set Frequency Band
- 4.5.7 Enable Carriers
- 4.5.8 Local R-Key Handling
- 4.5.9 No Transfer on Hangup
- 4.5.10 No On-Hold Display
- 4.5.11 Display Original Called
- 4.5.12 Early Encryption
- 4.5.13 Configure Coder
- 4.5.14 Secure RTP
- 4.5.15 Configure Supplementary Services
- 4.5.16 Select Mode
- 4.5.17 Set Master Id
- 4.5.18 Enable PARI Function
- 4.5.19 Set Region Code
- 4.5.20 Configure Gatekeeper
- 4.5.21 Registration for Anonymous Devices
- 4.5.22 Conferencing Unit
- 4.5.23 Select Crypto Master Mode
- 4.5.24 Select Mobility Master Mode
- 4.5.25 Connect Mobility Master to other Mobility Master(s)
- 4.5.26 Disconnect Mobility Master from other Mobility Master(s)
- 4.5.27 Connect Mobility Master to a Crypto Master
- 4.5.28 Connect Master to a Mobility Master
- 4.5.29 Enable the Radio
- 4.5.30 Enter IP Address to the PARI Master and the Standby PARI Master
- 4.5.31 Multiple Radio Configuration
- 4.5.32 PARI
- 4.5.33 SARI
- 4.5.34 Configure Air Synchronization
- 4.6.1 Add instance id to the user registration with the IP-PBX
- 4.6.2 IP-PBX supports redirection of registration when registered to alternative proxy
- 4.6.3 Use local contact port as source port for TCP and TLS connections
- 4.6.4 Session Timer (initial value)
- 4.7.1 Configure Messaging
- 4.7.2 Device Management
- 4.7.3 Service Discovery
- 4.7.4 Send Status Log
- 4.7.5 Module Fault List
- 4.8.1 Configure Automatic Firmware Update
- 4.8.2 Configure Logging
- 4.8.3 Configure the HTTP settings
- 4.8.4 Configure the HTTP Client settings
- 4.8.5 SNMP
- 4.8.6 Phonebook
- 4.8.7 Configure IP-DECT to Connect to a Presence System Using ICP
- 4.9.1 Show all Registered Users in the IP-DECT System
- 4.9.2 Search for User Information
- 4.9.3 Add a User
- 4.9.4 Add a User Administrator
- 4.9.5 Export the Users to a csv file
- 4.9.6 Show Anonymous
- 4.10.1 Radios
- 4.10.2 RFPs
- 4.10.3 Sync Ring
- 4.10.4 Sync Ports
- 4.10.5 Air Sync
- 4.10.6 Sync Lost Counter in IPBS
- 4.11.1 Air Sync Overview
- 4.11.2 Disturbances
- 4.11.3 Status
- 4.12.1 Display All Ongoing Calls in the System
- 4.12.2 Display Calls
- 4.12.3 Handover
- 4.13.1 General
- 4.13.2 Interfaces
- 4.13.3 SIP Interfaces
- 4.13.4 Gatekeeper Interfaces
- 4.13.5 Routes – Configuration
- 4.13.6 Show Active Calls
- 4.15.1 Before Upgrading
- 4.15.2 Upgrading Sequence
- 4.15.3 Software Upgrade from 2.X.X
- 4.15.4 Software Upgrade
- 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later
- 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later
- 4.21.1 Update Configuration
- 4.21.2 Update Firmware
- 4.21.3 Update the Boot File
- 4.21.4 Update the RFPs
- 4.26.1 Logging
- 4.26.2 Tracing
- 4.26.3 Alarms
- 4.26.4 Events
- 4.26.5 Performance
- 4.26.6 Config Show
- 4.26.7 Ping
- 4.26.8 Traceroute
- 4.26.9 Environment
- 4.26.10 RFP Scan
- 4.26.11 Service Report
- 4.27.1 Idle Reset
- 4.27.2 Immediate Reset
- 4.27.3 TFTP Mode
- 4.27.4 Boot
- 5 Commissioning
- 6 Troubleshooting
- 7 Related Documents
- Document History
- Appendix A: How to Configure and Use the Update Server
- Appendix B: Local R-Key Handling
- Appendix C: Database Maintenance
- Appendix D: Load Balancing
- Appendix E: Update Script for Configuration of Kerberos Clients
- Appendix F: Install Certificate in the Web Browser
- Appendix G: Used IP Ports
- Appendix H: Configure DHCP Options
TD 92579EN
15 October 2014 / Ver. M
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X)
93
4.12.2 Display Calls
All calls on an IPBS/IPBL can be displayed by selectin
g Traffic > Radio Calls. See the table
below for information about the different statistics fields.
4.12.3 Handover
During call, all ongoing handovers in the IP-DECT system can be displayed by selecting
T
raffic > Handover in the Master.
4.13 Gateway
IPBS/IPBL has the option to act as a SIP registrar. In fact IP-DECT has several gateway
interfaces that independently from each other can handle device registrations.
Gateways can be used to register to another device such as a gatekeeper in a PBX.
SIP interfaces can be used to obtain, for example, a trunk line from a SIP Provider. This
solution still requires handset VoIP registrations to be managed in IP-DECT - this is not
performed by the SIP provider.
Calls In The total number of incoming calls to the Master.
Calls In Delivered The number of connected incoming calls in the
Master.
Calls Out The number of outgoing calls from the Master.
Handover The number of handovers in the Master.
Handover Cancelled The number of cancelled handovers in the
Master. Occurs when the handset decides to stay
on the original Base Station.
Abnormal Call Release The number of abnormal call terminations. A call
release can occur if for example the user leaves
the system’s coverage area. To analyze the events,
select Diagnostics > Events. To analyze how calls
are connected and disconnected, select
Diagnostics > Logging and select the DECT
Master check box.
Busy Hour Call Attempts The number of calls under the busiest hour
counting from when pressing the Clear button.
Busiest hour start time The start time of the busiest hour counter which
was started when pressing the Clear button.
Radio
Calls In The number of incoming calls to the Radio.
Calls Out The number of outgoing calls from the Radio.
Handover The number of handovers in the Radio.
Handover Cancelled The number of failed handovers in the Radio.
NOTE: There can be several reasons for
uncompleted handovers occuring. This will in
most cases not cause dropped or disconnected
calls.