LF Location Units
11
3.2 L951LP Locator
3.2.1 Connecting Supply Voltage
16 - 40 V DC
15 - 28 V AC
6
5
4
3
2
1
Monitor
J01
out
in
J04
J05
1
2
1
2
Channel 2
Channel 1
LED03
LED01
LED02
P02
P01
S02
S03
S04
SW05
SW04
SW01 SW02
J01
1
6
1
1
3
3
12
3
1
2
1
8
1
8
SW03
L04
Figure 13. Connector J01, L951LP
Connect supply voltage to pin1 and 2 on J01 as shown in figure 13.
3.2.2 Setting Location Code
The location code consists of four
hexadecimal digits (0000 – FFFE) and is set with switches
SW01 and SW02. If a jumper is placed on S03 pins 2 and 3, channel 2 sends the master's
code +1. Otherwise, both channels send the same code.
SW01 and SW02 have eight switches each, divided into two gr
oups 1–4 and 5–8. Each
group corresponds to one hexadecimal digit.
Switches 5 – 8 (SW01) = first hexadecim
al digit (most significant)
Switches 1 – 4 (SW01) = second hexadecimal digit
Switches 5 – 8 (SW02) = third hexadecimal digit
Switches 1 – 4 (SW02) = fourth hexadeci
mal digit (least significant)
Switch 1 on SW02 is the least significant bit and switch 8
on SW01 is the most significant.