User's Manual

Table Of Contents
TD 93021US
17 July 2017 / Ver. PF3 87
Installation Guide
teleCARE IP
6.12.4 Mounting the NIPC2 Backplate
The backplate of the NIPC2 must be mounted over the back box using the holes in the corners of the
backplate in order to ensure that the NIPC2 is IP44 splash water proof.
6.12.5 Drilling the Backplate Mounting Holes
Four suitably sized holes should be drilled around the back box at 3in (77mm) between the centers (1). A
wall plug which will accept a screw of diameter 0.14in (3.5mm) to 0.15in (3.8mm) should be inserted in
each hole (2).
Figure 115. Drilling the backplate mounting holes
Note: The type and length of the screw depends on the type of wall and the wall plugs. The
diameter of the screw must not exceed 0.15in (3.8mm).
6.12.6 Mounting the Backplate on the Wall
The backplate should be placed over the back box, with the four holes in the corners of the backplate
lining up holes in the wall and with the side marked “UP” at the top.
Figure 116. Fixing the backplate to the wall
UP
NOTE:
The screws inside the
back box must not be
used to mount the
backplate. Four holes
must be drilled in the
wall surface and fitted
with suitable wall plugs
to allow the backplate
to be mounted using
the four corner holes.