6.2.1 Active Peripherals
Active peripherals are connected to one of the three room buses of a teleCARE IP room controller.
Each room bus provides eight addresses for the connection of teleCARE IP active peripherals as
described in the table below:
Table 2. Room bus addresses and applications
6.2.2 Passive Peripherals
Passive peripherals can be connected to those active peripherals which are equipped with a passive
bus connector. Passive peripherals do not require an address on the room bus as they are connected to
an active peripheral and therefore share the same address.
The table below shows an overview of all the interconnections that can be made between active and
passive peripherals.
Table 3. Active and passive peripherals interconnection scheme
Note: Only one Passive Pull-cord module can be connected per passive bus.
Room Bus Address Active Peripheral Address Setting
0 - 3 Doorside Modules
Bedside Modules
Pull Cord Modules
Medical Rail Socket
Set by DIP switch
4 Toilet Cancel Module Fixed
5 Slave Corridor Lamp
Duty Selector
6 Card Reader
6 + 7 Room Display
Active Peripherals with
Passive Bus Connector
Passive Peripheral Modules
Passive Pull Cord
NIPC-G/W3P
Passive Pull Cord
NIPC2-G/WAA
Passive Toilet Cancel
NITC-G/W2P
Doorside Module NIDM
••
Room Display NIRD
••
Toilet Cancel Module NITC
••