teleCARE IP
6.4 Doorside Module (NIDM)
The NIDM is an active switch module connected to room bus addresses 0, 1, 2 or 3. The address is set
by an on-board DIP switch. Each door side module contains a passive bus connector for the additional
(parallel) connection of at maximum two passive peripherals (NIPC or NITC + NIPC). Doorside modules
are equipped with a buzzer for the acoustic signaling of forwarded calls.
Figure 17. Doorside Module (NIDM)
The door side module includes a 5-pin connector for the connection of a speech module (NISP). For
details of the speech module refer to See “Speech Module (NISP)” on page 33.
6.5 Pull Cord Module (NIPC)
The pull cord module is an active switch module connected to room bus addresses 0, 1, 2 or 3. The
address is set by an on-board DIP switch.
The pull cord integrates a safety break mechanism accomplished with two red plastic balls. Pull cord
modules are designed for use in humid areas like bathrooms and toilets.
Figure 18. Pull Cord Module (NIPC)
IMPORTANT: At least one active NIPC module must be permanently located in the bathroom
of each resident apartment.
The pull cord module includes a 5-pin connector for the connection of a speech module (NISP). For
details of the speech module refer to See “Speech Module (NISP)” on page 33.