I&M008-10223_USER_layout 6/17/14 3:27 PM Page 1 Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings Installation and Maintenance Instructions © 2014 Ashcroft Inc., 250 East Main Street, Stratford CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0602 www.ashcroft.com All sales subject to standard terms and conditions of sale.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 2 © 2014 Ashcroft Inc., 250 East Main Street, Stratford CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0602 www.ashcroft.com All sales subject to standard terms and conditions of sale.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 3 TABLE OF CONTENTS 1. CAUTION 2. OVERVIEW 3. SPECIFICATIONS 4. DIMENSIONAL DRAWINGS 5. PRODUCT INSTALLATION 6. ASSEMBLY REMOVAL 7. PRODUCT MAINTENANCE / IN-SERVICE REPLACEMENT 8. STORAGE 1 - CAUTION CAUTION WARNING! READ PRIOR TO PRODUCT INSTALLATION AND/OR MAINTENANCE GENERAL: Use proper safety equipment and procedures when handling product.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 4 4 - DIMENSION DRAWINGS DIMENSION DRAWINGS Type 80 Wafer Isolation Ring W H Ø OD Ø ID Nominal Pipe Size Inner Diameter (ID) Outer Diameter (OD) Retrofit Width (XIR) Width (W) None Instrument Removal (H) Safe Needle Weight Quick Valve Lbs. Release 2˝ 2.07 4.00 2.13 2.00 1.89 2.04 1.70 4.0 3˝ 3.07 5.25 2.13 2.00 1.89 2.04 1.70 6.3 4˝ 4.03 6.75 2.13 1.50 1.89 2.04 1.70 8.0 6˝ 6.07 8.63 2.25 1.50 1.89 2.67 2.32 10.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 5 4 - DIMENSION DRAWINGS DIMENSION DRAWINGS (cont.) Type 81 Bolt-Thru Isolation Ring W H Ø ID Ø BC Ø OD Ø BD ANSI ASME Class 150 300 Nominal Inner Outer Pipe Diameter Diameter Width Size (ID) (OD) (W) 2˝ 3˝ 4˝ 6˝ 8˝ 10˝ 2˝ 3˝ 4˝ 6˝ 8˝ 10˝ 2.07 3.07 4.03 6.07 7.98 10.02 2.07 3.07 4.03 6.07 7.98 10.02 6.00 7.50 9.00 11.00 13.50 16.00 6.50 8.25 10.00 12.50 15.00 17.50 2.00 2.00 1.50 1.50 1.50 1.50 2.00 2.00 1.50 1.50 1.50 1.50 5 Bolt Bolt No.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 6 5 - PRODUCT INSTALLATION PRODUCT INSTALLATION MATERIAL COMPATIBILITY: Wetted material selection is critical to the product’s life cycle and reliability.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 7 Type 80 Wafer (Installed View) Type 81 Bolt-Thru (Exploded View) Gaskets, nuts and bolts provided by USER 7
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 8 Type 81 Bolt-Thru (Installed View) Prior to installation, please follow the recommended manufacturer procedure: A. Confirm process has been shut down with process pressure relieved and piping drained. B. Provide pipe flange gasketing, mounting bolts, lockwashers and nuts (not supplied by Ashcroft). Step 1: Isolation ring and flange gaskets should be centered between process piping flanges.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 9 Step 3: Tighten the piping flange bolts to the locking nuts / washers on the opposite flange. Each should be tightened by cross-bolting with the proper torque based as described in ASME PCC-1 on NPS, ANSI/ASME Class rating, and gasketing used.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 10 C. Loosen flange bolts securing the isolation ring assembly to the process pipe flange. D. Upon separation of pipe flanges, remove assembly and flange gaskets from the piping. In the event only instrument removal is required, use a wrench to unthread the instrument. Use container to catch the fill fluid when draining from the isolation ring.
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 11 11
I&M008-10223_USER_layout 6/17/14 3:27 PM Page 12 Ashcroft Inc., 250 East Main Street Stratford, CT 06614-5145 U.S.A. Tel: 203-378-8281 Fax: 203-385-0408 (Domestic) Fax: 203-385-0357 (International) email: info@ashcroft.com www.ashcroft.com I&M008-10223-6/14 Visit our web site www.ashcroft.