User guide

Installation and Maintenance Instructions
for Ashcroft A-Series Miniature
Explosion Proof Pressure Switches
INTRODUCTION
The APS and APA pressure switch have 316 stainless steel
housing and process connections. The APS has a factory fixed
setpoint which cannot be changed in the field. The APA is field
adjustable and can easily be adjusted by following the instruc-
tions in the diaphragm above.
ELECTRICAL CONNECTION
The APS and APA switch is available with wire leads and con-
duit connections. Refer to the figure on other side for wiring
color codes.
Only trained and skilled personnel are allowed to attach the
wires to the electrical terminals of the switch.
Cable couplers, glands and conduit connectors must have the
correct electrical approvals as required by local electrical codes.
The ground wire/connector is connected to the switch housing.
MICRO SWITCH RATINGS
CODE VAC RATING VDC RATING
H 5A @ 125/250VAC
5A @ 28Vdc resistive
3A @ 28Vdc inductive
P 3A @ 125VAC 2A @ 30Vdc resistive
G 0.1 A @ 125VAC 0.1A @ 30Vdc resistive
L 1A @125VAC
1A @ 28Vdc resistive
0.5A @ 28Vdc inductive
© 2012 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499, www.ashcroft.com
All sales subject to standard terms and conditions of sale.
I&M009-10046 (250-2966) Rev. 07/13
SLIDE COVER DOWN TO ACCESS
SETPOINT ADJUSTMENT SLIDE COVER
UP TO CLOSE AND SEAL ADJUSTMENT
ROTATE LEFT
<
TO INCREASE SETPOINT
ROTATE RIGHT
>
TO DECREASE SETPOINT
Ø .095 OR SMALLER TOOL
REQUIRED TO ROTATE NUT
APA APA APS
LOOK FOR THESE MARKS ON OUR PRODUCTS
Sira 13ATEX1123X
IECEx
CSA 13.0015X
SIL 3 C APABLE