INSTALLATION MODEL IN SOLID FUEL BURNING FIREPLACES
This model may be installed in a masonry replace. The gure below demonstrates the required dimensions.
NOTE: See “Producing Adequate Air for Combustion And Ventilation”
NOTE: Installer of this appliance must mechanically (peel and stick) attach marking supplied with this unvented
appliance before installing to inside of rebox of solid-fuel burning replace or listed ventless rebox enclosure
into which unvented replace insert is installed. See example of marking on the “Gas Pressure Check” section
of this manual.
CAUTION: Cutting any sheet-metal parts of solid-fuel burning replace or listed ventless enclosure in which
unvented replace is to be installed is prohibited.
NOTE: “If factory-built replace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5) diameter
or less may be drilled through lower sides or bottom of rebox in a proper workmanlike manner. This access
hole must be plugged with non-combustible insulation after the gas supply line has been installed.”
“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable) can be removed
from replace before installing unvented replace insert.”
NOTE: After the unit is positioned in replace, mark trim panels as follows:
A. Set side panels in place, at against replace. Mark down inside edge of trim panel to make a vertical
reference line.
20"
24"
7"
7"
RIGHT
SIDE
LEFT
SIDE
25 1/8”
35-9/16”
13-3/4”
FRONT
CEILING
SECTION III