Installation Guide

14
WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING FIREPLACE, THE CHIMNEY FLUE AND
FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES AND LOOSE PAINT BY A QUALIFIED
CHIMNEY CLEANER.
CAUTION: ANY OUTSIDE AIR DUCTS AND/OR ASH DUMPS IN THE FIREPLACE SHALL BE
PERMANENTLY CLOSED AT TIME OF APPLIANCE INSTALLATION.
WARNING: SOLID-FUELS SHALL NOT BE BURNED IN A FIREPLACE IN WHICH AN UNVENTED
ROOM HEATER IS INSTALLED.
INSERT KEYS BEHIND FLANGE OF TRIM AS
SHOWN. BLANK CORNER KEY MUST BE IN-
STALLED FIRST. INSERT SECOND KEY. ADJUST
TRIM AND TIGHTEN SET SCREWS.
INSERT FIREPLACE FACADE INSTALLATION
1. Position stove in replace. Align facade panels with replace and top of stove. The panels should be at
against the replace and standing vertical.
Notes: The facade must be installed before unit is set into its nal position.
2. Mark the location of the facade panels along the top of the stove with a pencil. The mark will be used
to realign the panels later.
3. Slide stove out of replace far enough to be able to work behind facade panels.
4. Realign the rst side panel with the mark made previously.
5. Using the predrilled holes in the facade panel as a guide; mark and drill holes for the self tapping screws
used to mount the facade panel. See illustration
on right.
Note: Align the mounting screws with the center of
the predrilled holes to allow for adjustment.
6. Repeat steps 4 and 5 for the other side panel.
7. Attach side panel trim as shown. See illustration
on right.
8. Ensure venting is attached properly.
9. Align the top panel with the side panels and screw
each side together use self tapping screws to
attach the surround top to the stove.
10. Attach top panel trim.
Note: Stove and facade panels should realign
with replace to allow the panels to be at against
replace and standing vertically