Installation Guide

18
Board Retainers
Gas Unit
Brick Boards
STEP 7 Return the ame shield and then the gas unit by following steps two and three in reverse.
STEP 8 Replace Gas Unit. Check to ensure there are no gas leaks.
INSTALLATION OF OPTIONAL BRICK PANEL KIT
To install the Brick Panel Kit follow the instructions below:
STEP 1 Unhook gas line.
STEP 6
Insert board retainers
STEP 2
Remove gas unit by removing two screws one on
the left and right side of the burner.
STEP 3
Remove the ame shield by taking out the four screws.
Keep this peace and hardware as it will be reinstalled.
STEP 4
Remove the insulations shield and insulation panel by taking out the four
screws. These items are no longer needed and may be discarded.
Warning:
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
Flame Shield
Insulation Shield
STEP 5
Insert brick board