OBSERVED PROBLEM POSSIBLE CAUSE SOLUTION
Heater produces a clinking/
ticking noise just after burner is lit
or shut off
Metal expands while heating or contracts
while cooling
This is common with most heaters. If
noise is excessive, contact a quali ed
service person
Heater produces unwanted odors Heater burning vapors from paint, hairspray,
glues, etc. (See Important above)
Ventilate room. Stop using odor causing
products while heater is running
Low fuel supply Re ll supply tank
Gas leak (See WARNING above) Locate and control all leaks (See Checking
Gas Connections)
Heater shuts off in use (ODS
operates)
Not enough fresh air is available Open window/door for ventilation
Low line pressure Contact local propane co.
ODS/Pilot is partially clogged Clean ODS/Pilot
Gas odor even when control knob
is in OFF position
Gas leak (See WARNING above). Locate and correct all leaks (see Checking
Gas Connections)
Control valve defect Replace control valve
Gas odor during combustion Foreign matter between control valve and
burner
Remove foreign matter from gas tubing
Gas leak (See WARNING above) Locate and correct all leaks (see Checking
Gas Connections)
WARNING:
IF YOU SMELL GAS:
SHUT OFF GAS SUPPLY
DO NOT TRY TO LIGHT APPLIANCE
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S
PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.