Operating Manual - nX, nXe, and nXp Power Ampliers
6 nXe SERIES REAR PANEL FEATURES
The following nXe features are in addition to standard features found in nX series ampliers:
6.1 Ethernet Port - This RJ-45 connector offers Ethernet control and monitoring of the amplier using Protea
ne
soft-
ware. See section 8 in this manual for details on Ethernet communications.
6.2 Network Audio -
This is for an optional factory installed CobraNet or Dante
network audio
module on nXe and nXp models. See section 13 for details.
6.3 Standby - The STBY pin, when connected to the ground pin (G) as shown, will remotely
place the amp into standby mode. When the connection is opened, the amplier returns to normal opera-
tion. The front panel power switch will ash when the amplier is in standby.
6.4 Fault - Four Fault pins are used with adjacent
ground (EG) and +5V pins for 5V logic outputs, and are
assigned in software <Device Options> to indicate an amplier fault state. The
assignable fault conditions are overtemperature, rail voltage, and average power,
the same conditions that could place the amplier into protect mode. Logic low
(0V) indicates fault condition. In the rst example to the right, a remote red
LED is wired to F1 and +5V and turns on when a user-assigned fault condition
exists. F1 is normally high (+5V) but goes low (0V)
on fault. The second example uses a green LED wired
to F2 and EG to indicate no-fault, so the LED remains
on unless there is a fault. In the third example, a relay
circuit is driven by the F1 pin in order to switch on
a room or rack exhaust fan if the amplier becomes
severely overheated. Maximum fault pin source current
is 20mA per pin. Maximum fault pin sink current is
200mA. Use an external +5V supply as shown if sink
current exceeds 200mA.
6.5 Preset -
Each pin (P1 through P4) can be connected to the adjacent ground pin (G) via Ashly's WR-2 remote or other contact
closure to recall a stored preset or sub preset from the amplier. Preset pins 1-4 correspond directly to amplier presets 01 - 04.
6.6 Serial Data Connector -
These four pins (G, +18, OUT, IN) are for connecting a serial data remote control such as an
Ashly WR-5 or RD-8C. Ashly also offers an in-line converter called the INA-1 which allows the data port to be used with third party RS-232
controllers. A technical RS-232 protocol document is available on the Ashly website for third party developers. See more data remote control
application details in section 10.
6.7 AUX Outputs -
These Euroblock connectors provide preamp signals for driving other ampliers. See the block
diagram on page 59 for the differences between two and four channel amplier AUX outputs. AUX outputs are pseudo-balanced,
meaning they use single ended signal with balanced impedance, and can be wire balanced or unbalanced.
6.8 AES3 Digital Audio I/O Option -
This is used for Ashly's two or four channel AES3 input and pass-through
module, available as a factory installed option on nXe and nXp models. See section 12 for AES3 details.
6.4 Fault Logic Application Examples
6.3 Standby Switch