[Add Item>Control Objects] - Stand-alone control objects can be added to the canvas and linked to control specic
device functions. They include Level Fader, Signal LED, Level Meter, Preset Button, Standby Button, Mute Button, Logic Out
Button, and Source Select Button.
[Add Item>Display Objects] - Text and image les can be added to the canvas.
9.1g Options Menu
[Options>Auto Add Online Devices] - When this is checked On, all network devices appear on the canvas whenever
the software is launched or when the networked is scanned for devices.
[Options>Display Grid] - Turns on or off the project canvas grid
[Options>Auto-Close Preset Recall Messages] -
Any device that recalls a preset will trigger a message that appears on
the canvas. If this is checked On, those messages will go away automatically, otherwise they will stay on the display until closed
by the user.
9.1h Flash Programmer Menu
[Flash Programmer>Launch Flash Programmer] - This is used to update the rmware on any networked Ashly
device. All available rmware update les can be downloaded from the Ashly website.
[Flash Programmer >Launch WR-5 Flash Programmer] - WR-5 rmware must be updated through its hosting
device, since WR-5 remote controls are not themselves networked. Download the new WR-5 rmware, select the host device,
and follow the instructions.
9.1i Load Analysis Menu - Load Analysis is a software tool used to visualize the swept AC impedance of a given
loudspeaker, and to test the integrity of a potentially damaged loudspeaker or connection. Load impedance analysis works by
formulation of speaker output measurements taken when a user dened swept sine wave input is applied to one amplier channel
by software. Currently, the only Ashly ampliers with load analysis are NE two-channel (dsp) and nXp.
Loudspeakers are specied with a nominal impedance rating, 8 Ohms for example. This is an average rating, the actual
impedance across it's frequency range can vary substantially above or below 8 Ohms due to
inductance, resonance, and other
properties which affect impedance
. Lower impedance, even within a narrow frequency range, can increase the amount of am-
plier current delivered to the speaker. This can present a problem when wiring multiple speakers in parallel, as the combined
speaker impedance may become so low that it causes the amplier to go into overcurrent protection mode and shut down. The
way to avoid this is to pay attention to the lowest measured impedance rather than the nominal impedance rating for a given
speaker load, and make sure the amplier is rated to drive that load.
A second function of load analysis is for troubleshooting loudspeakers. When loudspeakers are damaged by overheated
voice coils, torn cones or surrounds, mechanical damage from being dropped, or have corroded connections, they can exhibit
different load impedance characteristics than when new. An initial load impedance analysis can be performed when the system
is rst installed and the results saved to disk for reference. Future load impedance tests can be compared to the original reference
data and issue a pass/fail rating based on a user-dened percentage of similarity to the original data. Load anaylsis can thus help
determine if loudspeakers are damaged or disconnected, and can be administered from a remote network location.
Keep in mind that this test is a real time audible event, so be certain that all test parameters, particularly volume (sweep
level) and frequency range (sweep start/sweep stop), are suited for the speakers under test, and that the venue is ready for a brief
period of test tones at potentially signicant volume. Note: During the test, all audio DSP processing in the amplier is stopped.