Owner`s manual

45
Operating Manual - nX, nXe, and nXp Power Ampliers
11 ASHLY REMOTE CONTROL DEVICES
In addition to iPad control, the following Ashly devices are available for remote control of amplier functions.
11.1 WR-1 Level Control (All nX models) - The WR-1 is a dual potentiometer remote volume control
designed to t in a standard wall electrical box, and is wired to the amplier back panel Euroblock connector labeled
“CH (1-4) Remote DC Level” using four conductor wire. If wiring a custom potentiometer other than the WR-1, connect
+5V from the remote level control Euroblock connector to the potentiometer's CW pin, GND to the CCW pin, and the
channel under control to the wiper. Do not connect the WR-1 remote level control ground to any other external grounds.
11.1 - WR-1 Assembly
11.1a - WR-1 Wiring
11.2 WR-1.5 Level Control and Preset Recall Switch
(Level Control all models, preset recall on nXe and nXp models only) -
The WR-1.5 has a four position rotary switch for selection of stored amplier
presets 1-4, and a potentiometer for remote DC level control of one amplier
channel. Clear windows are provided for user generated labels.
11.2 - WR-1.5
11.3 WR-2 Preset Recall Switches (nXe and nXp only) -
The WR-2 allows selection of stored amplier presets 1-4 using pushbutton
switches. Each pushbutton switch is connected to a preset recall pin on the
back panel of the amplier under control. The terminal numbers correspond
to the rst 4 preset memory locations in the controlled amplier. Pressing a
button will select and load the corresponding amplier preset. Clear windows
are provided for a user-generated label.
11.3 - WR-2