Owner`s manual
Operating Manual - nX, nXe, and nXp Power Ampliers
48
12 AES3 DIGITAL AUDIO INPUT/PASS-THROUGH
nXe and nXp ampliers support factory installed two or four chan-
nel AES3 input options, named OPAES2* and OPAES4*. The AES3
format uses two channels of digital audio transmitted over a single cable,
maintaining a completely digital signal path into the amplier stage or
into the DSP stage if DSP is installed. Two channel ampliers accept
a two channel input with pass-through, while four channel ampliers
accept four input channels with pass-through. There is no AES3 output
available from the amplier's DSP section, only pass-through of the input.
48kHz and 96kHz AES3 data rates are currently supported. The ampli-
er's internal sample rate must match the incoming AES3 sample rate (section
9.2h). A bicolor LED beside the AES3 connector indicates "Lock" (green)
or "Error" (red) as long as the AES3 receiver is active and is providing the
master clock source. The software AES3 control panel (shown below) shows
the status of the AES receiver in greater detail.
12.1 Source Selection The input must be congured via soft-
ware to accept the AES3 source before it can be used. See section 9.4e.
12.2 Cable Specication Standard 110 ohm microphone cable
(3 conductor) with standard XLR connectors will support AES3 data transmission up to 100 meters.
12.3 Hardware Status Indicators
AES Status LED (green) - Receiver Rx1 is "Active", has locked onto an incoming AES/EBU signal, and data is
ready for processing. This LED is disabled when network audio provides the master clock.
AES Status LED (red) - Receiver Rx1 is "Active" but has an error. AES Signal
will be muted. See "Errors Since Reset" for specic error.
12.4 Software Status Indicators The AES/EBU status is found under the Device
Options>DSP Options menu:
AES3 Input Status (green): Receiver is "Active" and has locked onto an incoming
AES/EBU signal and data is ready for processing.
AES3 Input Status (red): Receiver is "Active" and has an error. See "Errors Since
Reset" for specic error.
Detected Sample Rate: Sample rate at which the AES/EBU receiver is locked.
Errors Since Reset: This displays AES3 data errors that have occurred during run
time. Error indications are latching, meaning they remain on even after the error condition
has been corrected, useful when diagnosing intermittent problems. Error indications are
cleared by pressing [Reset Errors] or by cycling power.
AES/EBU Parity Error: Parity error with incoming signal
AES/EBU Non-Audio Error: Incoming signal is not audio
AES/EBU Sample Rate: Unable to lock onto incoming frequency
AES/EBU Invalid Error: Incoming signal is invalid
AES/EBU Lock Loss Error: Unable to lock onto incoming signal, or lost lock of incoming signal
AES/EBU Sample Rate Mismatch: Receiver frequency does not match DSP frequency.
AES/EBU Non-PCM Error: Invalid AES format
*To use an OPAES2 or OPAES4 option in an nXe amplier (no DSP), the OPDAC4 must also be ordered and in-
stalled by the factory. The OPDAC4 is not required on nXp models.
OPAES2 and OPAES4 AES3 Options
AES3 Software Control Panel