ne800 ne800.10 ne800.70 ne800.25 ne1600 ne1600.10 ne1600.70 ne2400 ne2400.10 Network Enabled Two Channel Power Amplifiers Operating Manual ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580-9103 Phone: (585) 872-0010 Toll-Free: (800) 828-6308 Fax: (585) 872-0739 www.ashly.
Operating Manual - NE Two Channel Power Amplifiers Table Of Contents 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 THE NE TWO CHANNEL AMP SERIES ne800 Models . . . . . . . . . . . . . . . . . . . . ne1600 and ne2400 Models . . . . . . . . . . Amplifier Options Overview . . . . . . . . . . Protection . . . . . . . . . . . . . . . . . . . . . . . Physical Description . . . . . . . . .
Operating Manual - NE Two Channel Power Amplifiers 1. INTRODUCTION Thank you for your purchase of this NE (network enabled) two channel power amplifier. Ashly NE power amplifiers combine lightweight, state of the art, high efficiency switching technology with integrated Ethernet control, and use optional modular expansion cards to provide comprehensive internal DSP processing, AES/EBU input, and networked digital audio (CobraNet) input.
Operating Manual - NE Two Channel Power Amplifiers ne1600 ne1600 Models Stereo Mode Both Channels Driven 20Hz - 20KHz 1% THD Bridged Mode RATED WATTS RATED VOLTS ne1600.10 RATED LOAD Ω RATED WATTS RATED VOLTS RATED LOAD Ω RATED WATTS RATED VOLTS RATED LOAD Ω 800 100 12.5 800 70 6.1 450 60 8 512* 64* 8* 613 70 8 800 56.6 4 256* 32* 4* 522* 45.7* 4* 400* 28.3* 2* 128* 16* 2* 261* 22.9* 2* 1600 113 8 1600 200 25 1600 140 12.3 ne2400 ne2400 Models ne1600.
Operating Manual - NE Two Channel Power Amplifiers Protection Ashly NE two channel power amplifiers come standard with several protection circuits: Over Current Protection - Is controlled in the output stage. Thermal Protection - When the internal temperature is below 40°C the fan runs at its slowest speed. Above 40°C the speed is increased until it reaches its maximum value. If the temperature exceeds 100°C, the input on that channel is reduced.
Operating Manual - NE Two Channel Power Amplifiers Amplifier Rear Panel 1. Optional CobraNet CNM-2 Card or AES/EBU Input Slot – Installation of an optional CobraNet CNM-2 card option allows this amplifier to be part of a CobraNet audio network. Installation of the AES/EBU input option in this slot allows for digital audio input in the AES/EBU format. 2. Ethernet Port - This offers 10/100 Ethernet control and monitoring of amplifier functions using Proteane software. 3.
Operating Manual - NE Two Channel Power Amplifiers Requirements Ashly NE two channel amplifiers have specific physical, electrical and signal requirements for proper operation. These requirements will vary depending on your specific application, setup, and the settings on the amplifier. When setting up and testing your system, please take special care to double check all connections and settings. Please refer to the specifications section of this manual for specific input, output and other figures. 4.
Operating Manual - NE Two Channel Power Amplifiers 5. PROTEAne SOFTWARE Proteane software offers a comprehensive suite of tools for controlling Ashly NE amplifiers as well as other Ashly products. The standard NE two channel amplifiers allow for Ethernet control and monitoring of power functions, level, mute, polarity, and live speaker load analysis.
Operating Manual - NE Two Channel Power Amplifiers 5) Attenuators - These two dials indicate the physical position of hardware controls on either the amp front panel or the remote level control (if present). Note that these will display the position of attenuators even when DISABLED in software. 6) Total Attenuation - This indicates the total amount of attenuation being applied to the channel.
Operating Manual - NE Two Channel Power Amplifiers Proteane Two Channel Amplifier DSP Control Surface (DSP option must be installed) 6) Output Mixer - For a given amplifier output channel, all inputs that have been routed in the matrix router are mixed together here. 7) Pluggable Output DSP Tools - Output DSP tools are the same as those available to the inputs. 8) Output Mute Button - Mutes the output. 9) Output Channel Name - The user can name each output channel.
Operating Manual - NE Two Channel Power Amplifiers Distortion (SMPTE, typical) - 8 ohm load, 10dB below rated power: . . . . . . . . . . . . . . . Distortion (THD-N, typical) - 8 ohm load, 10dB below rated power, 20Hz-20kHz: . . . . . Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Damping Factor (8 ohm load, <1kHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input Impedance . . . . . . . . . . .
Operating Manual - NE Two Channel Power Amplifiers (DSP SPECIFICATIONS, continued) 10, 6, 4, or 2 Band Parametric Filter Types Parametric: Frequency: . . . . . . . . . . . 20-20kHz Level: . . . . . . . . . . . . . . . -30dB to +15dB Q Value: . . . . . . . . . . . . . 0.016oct to 4oct Hi/Low Shelf 6/12 dB Frequency: . . . . . . . . . . . 20Hz-20kHz Level: . . . . . . . . . . . . . . . -15dB to +15dB TOOLS Audio Meter Range: . . . . . . . . . . . . . . -60dBu to +20dBu Increments: . . . . . . . . . . .