You may also use the position last computed by the
receiver and declare it as the base position by tapping on
the Current Position button. You then have to enter a Site ID
for this position. Also in that case, when leaving the
Position tab, ProMark Field will ask you whether you wish
to save that point to the job file or not.
Tap on the Link tab and select the device through which
RTK corrections will be generated and delivered to rovers.
Make the required settings depending on the choice of
device made. See table below.
Tap on the Format tab and choose the format of the
corrections the base will generate and deliver (Eight
possible choices: RTCM3.0, RTCM2.3 (DGPS), RTCM2.3
(RTK), CMR, CMR+, ATOM, ATOM compact or ATOM
super compact).
Tap on the Station tab: Enter the Station ID for the base.
This number is left to the user’s choice but the following
ranges of Station ID values are recommended depending on
the selected data format:
Recording tab: Although operated as an RTK base, the
receiver can also collect raw data. In that case, enable the
Record raw data for post-processing function, check that you
are using the desired storage medium (it is a good practice
to use a Storage Card) and choose the recording interval
(default: 1 second).
NOTE: Changing the storage medium requires that you
temporarily disable the Record raw data for post-processing
Device Settings
UHF radio Type, baud rate, advanced
GSM (CSD) modem None
Network connection
via GSM (GPRS) modem
Direct IP parameters:
Host, port
Or NTRIP parameters:
Host, port
Password, station
Other external device Port, baud rate
Format Station ID
RTCM 3.0 0-4095
RTCM2.3 0-1023
CMR, CMR+ 0-31
ATOM 0-4095