Specifications
Operation 5
Operation
 2
Operation
This chapter describes receiver operations other than those available through the front 
panel.
Receiver Initialization
It is good practice to reset your receiver prior to operating it for the first time or when a 
system malfunction occurs. A reset of the internal memory clears the memory and restores 
the factory defaults. This reset does not affect data stored on the PCMCIA card. Send this 
command to execute the initialization:
$PASHS,INI,5,5,5,5,1,0
For more information about this command, refer to Chapter 6, Command/Response 
Formats.
Setting Receiver Parameters
All user parameters may be set or changed by sending commands to the receiver serial 
port. Refer to Chapter 6, Command/Response Formats for more information about these 
commands. In the Z-Surveyor and the Z-FX receivers, many parameters are accessible 
through the front panel LED display. Refer to your individual receiver operations manual 
for more information.
Saving Parameter Settings
Ordinarily, receiver parameters that have been changed will return to their default status 
after a power cycle. The Z-Family of receivers allows you to save changed receiver 
settings so they will be saved through a power cycle. Perform the following steps to save 
receiver settings:
1. Send the receiver command: $PASHS,SAV,Y.
2. This command will save any parameters that have been modified from their 
default values before the command is issued. For more information about this 
command, refer to “SAV: Save User Parameters” on page 109.