Specifications

ASIX ELECTRONICS CORPORATION
18
AX88772
USB to 10/100 Fast Ethernet/HomePNA Controller
6.0 USB Commands
There are three command groups for Endpoint 0 (Control Endpoint) in AX88772:
The USB standard commands
The USB vendor commands
The USB Communication Class commands
6.1 USB Standard Commands
The Language ID is 0x0904 for English
PPLL means buffer length
CC means configuration number
I I means Interface number
AA means Device Address
Setup Command Data Bytes Access
Type
Description
8006_00 01 00 00 LLPP PPLL bytes in Data stage Read Get Device Descriptor
8006_0002 0000_LLPP PPLL bytes in Data stage Read Get Configuration Descriptor
8006_0003_0000_LLPP PPLL bytes in Data stage Read Get Supported Language ID
8006_0103_0904_LLPP PPLL bytes in Data stage Read Get Manufacture String
8006_0203_0904_LLPP PPLL bytes in Data stage Read Get Product String
8006_0303_0904_LLPP PPLL bytes in Data stage Read Get Serial Number String
8006_0403_0904_LLPP PPLL bytes in Data stage Read Get Configuration String
8006_0503_0904_LLPP PPLL bytes in Data stage Read Get Interface 0 String
8006_0603_0904_LLPP PPLL bytes in Data stage Read Get Interface 1/0 String
8006_0703_0904_LLPP PPLL bytes in Data stage Read Get Interface 1/1 String
8008_0000_0000_0100 1 bytes in Data stage Read Get Configuration
0009_CC00_0000_0000 No data in Data stage Write Set Configuration
810A_0000 _I I00_0100 1 bytes in Data stage Read Get Interface
010B_AS00_0000_0000 No data in Data stage Write Set Interface
0005_AA00_0000_0000 No data in Data stage Write Set Address
Table 3: USB Standard Command Register Map