Installation Guide

Installation instructions
Gas hobs
05
E
E/F
C
D
G
B
A
F
H
A
B
C
D
A (mm) B (mm) C (mm) D (mm)
HG16 min. 650 min. 600 min. 450 min. 120
HG17 min. 650 min. 750 min. 450 min. 120
HG19 min. 650 min. 900 min. 450 min. 120
A (>mm) B (mm) C (mm) D (>mm) E (>mm) F (>mm) G H
HG16 600 560 490 60 50 50 55 100
HG17 600 560 490 60 50 50 55 100
HG19 600 860 490 60 50 50 55 100
The gas connection must comply with national and local regulations.
The hotplate can be connected with rigid pipe as specified in
AS/NZS 5601.1current edition.
When the appliance is connected with a hose assembly,
the supply point shall be accessible with the appliance installed.
240 V - 50 Hz - max. 20 W
This appliance must be earthed
The electrical connection must comply with national and local regulations.
1/2” ISO 228 / 1/2" ISO 7-1
Free space around appliance
The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations.
See the data plate for information regarding the total gas consumption, gas type and gas pressure.
Rangehoods and exhaust fans shall be
installed in accordance with
manufacturers instructions.
For an overhead exhaust fan A>750 mm!
Gas connection
Important information
Pictograms used
Electrical connection
A
B
C
D
A (mm) B (mm) C (mm) D (mm)
HG16 600 526 48 520
HG17 750 526 48 594
HG19 900 526 48 514
y
y
x
x
>60º C
<60º C
oven
oven
Accessibility!
Y:
metal
Gas supply valve
shall be accessible
X:
safety hose
Gas supply valve
shall be accessible
Preparations for installation

en (04-16)

Summary of content (2 pages)