Service manual

8
INSTALLATION
WATER CONNECTION
The machine is plumbed in with the connection
hose that comes with it. The water pressure shall
be 0.1-1MPa (approx. 1-10kp/cm2 ; 10-100N/
cm2).
The water supply must have a stop cock. If the
piping is new, it can be advisable to first thorough-
ly flush it through so that any dirt will be flushed
out. Otherwise, any dirt in the piping could block
the filter in the machine's inlet valve and stop the
water supply.
DRAIN CONNECTION
The machine is delivered with a connected drain
hose that shall be connected to a suitable sink or
other drain connection. The height shall be 500 -
900 mm above floor level. Make sure the drain
hose does not kink.
ELECTRICAL INSTALLATION
The electrical installation must be carried out by
a qualified tradesman. Installation is by means of
a plug to an earthed wall outlet, or by a fixed
installation cable with all-pole switching.
Connections on delivery
The machine is supplied for single-phase 230V
use with a plug, heating element power 2000 W
and fused at 10 A. If an earth fault breaker is in-
stalled, it should be of type A.