SECTION III
INSTALLATION OF LOGSET WITH
(OPTIONAL) HEAT SHIELD MODEL 19HS
For installation of gas supply see “Fireplace and Gas Connection” in Section II, page 8.
NOTE: Centrally locate the Heat Shield in the fireplace and place it deep enough into the
fireplace to accomplish adequate draft (if use as a vented heater is planned). Ensure that the
Heat Shield front is inside the front edge of the fireplace, see Figure 8. Using the screws and
anchor provided, fasten the Heat Shield to the floor of the fireplace. On each side of floor
frame of Heat Shield base, there is a “go through hole”. Position the Heat Shield as
described above. Mark the hole for drilling. See Figure 8.
NOTE
:
When using Log Sets with optional Heat Shield the following minimums must be met:
18 - Front 25" - Rear 23" - Height 20" - Depth 19 1/2"
24 - Front 30" - Rear 29" - Height 20" - Depth 19 1/2"
30 - Front 36" - Rear 32" - Height 20" - Depth 19 1/2"
To avoid any movement of the gas log set during operation, screw the base to the floor of the
fireplace using the screws provided. Then follow log positioning in Section II.
NOTE: For the first few hours of burning, you will have a paint and burning smell. It is
recommended to leave the fan off during this period. You may also want to raise a
window or open the doors.