SAFETY INFORMATION
WARNINGS
IMPORTANT: READ THIS OWNER'S MANUAL CAREFULLY AND
COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE
APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY
OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE
POISONING.
Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or
nausea. If you have these signs, the heater may not be working properly. Get fresh air
at once! Turn off gas. Have burner serviced. Some people (such as preg-
nant women, persons with heart or lung disease, persons with anemia, those under the
influence of alcohol, and those at high altitudes) are more affected by
carbon monoxide than others. Make certain you understand and read all
Warnings. Keep this manual for reference. It is your guide to safe and proper operation of
these logs.
1. Install log set only in a solid-fuel-burning masonry fireplace or U.L. listed pre-
fabricated fireplace constructed of non-combustible materials.
2. The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
3. This appliance may be installed in an After Market* Manufactured (Mobile) Home,
where not prohibited by state or local codes.
(* After Market: Completion of sale, not for purpose of resale from the manufacturer.)
NOTE: This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
NOTE: See Section IV for Mobile Home Installation and Producing adequate Combustion and
Ventilation Air.
IMPORTANT: VENT-FREE HEATERS ADD MOISTURE TO THE AIR. ALTHOUGH
THIS IS BENEFICIAL, INSTALLING HEATER IN ROOMS WITHOUT ADEQUATE
VENTILATION MAY CAUSE MILDEW TO FORM FROM TOO MUCH MOISTURE.
4. Never install the log set:
-in a recreational vehicle.
-where curtains, furniture, clothing, or other flammable objects are less than 42" from the
front of the heater.
-in high traffic areas or in windy areas.
NOTE: These log sets comply with both the ANSI Z21.11.2b-2010 "Unvented Room
Heater" and ANSI Z21.60b-2004. CSA 2.26-2004 Decorative Appliance For "Solid Fuel
Burning Fireplace".
“WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.”