Owner`s manual

Page 4
5. Two models are available. One specific model for propane (LP) and one for natural gas.
Use the correct gas type for your home. This unit is not field convertible.
6. If these gas logs are for use with propane gas, do not place propane supply tank(s) inside
any structure. Locate propane supply tank(s) outdoors.
7. If you smell gas:
-Shut off gas supply.
-Do not try to light any appliance.
-Do not touch any electrical switch; do not use any phone in your building.
-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
-If you cannot reach your gas supplier, call the fire department.
8. When operated for the first time, the logs may emit a "paper burning" smell. This smell
will gradually diminish and will be totally eliminated after the first few hours of
operation. Run the gas logs with the flue damper open during this time. Do not use the
blower at this time.
9. "This heater shall not be installed in unusually tight construction unless provisions are
provided for adequate combustion and ventilation air. "See Section V - “Producing
Adequate Combustion and Ventilation Air”, page 34.
10. Surface of gas logs becomes very hot when operating. Keep children and adults away
from hot surface. Gas logs will remain hot for some time after shutdown. Allow surface
to cool before touching.
11. Never place any objects on these gas logs.
12. These gas logs MUST NOT BE USED with glass doors in the closed position.
13. If equipped, fresh air damper must be closed.
14. Keep appliance area clean and free from combustible materials, gasoline, and other
flammable vapors and liquids. Keep burner and control compartment
clean. See installation and operating instructions accompanying heater.
15. If burner shuts off, do not relight until you provide fresh outside air. If burner keeps
shutting off, have unit serviced.
16. An unvented room heater having input rating of more than 10,000 BTU per hour
shall not be installed in a bedroom or bathroom.
17. Maintain clearance around air openings.
WARNING: This appliance is equipped for (natural or propane) gas. Field conversion
is not permitted.