“WARNING: THIS APPLIANCE IS FOR INSTALLATION ONLY IN A SOLID FUEL
BURNING MASONRY OR UL127 FACTORY BUILT FIREPLACE OR IN A LISTED
VENTLESS FIREBOX ENCLOSURE.
IT HAS BEEN DESIGN CERTIFIED FOR THESE INSTALLATIONS. EXCEPTION:
DO NOT INSTALL THIS APPLIANCE IN A FACTORY BUILT FIREPLACE THAT
INCLUDES INSTRUCTIONS STATING IT HAS NOT BEEN TESTED OR SHOULD
NOT BE USED WITH UNVENTED GAS LOGS.”
INSTALLATION AND CLEARANCES
To ensure a safe installation into an existing solid fuel burning fireplace, the following
instructions must be carefully followed.
NOTE: Gas control knobs are located on right side facing unit.
1) Side wall Clearances:
Clearance from the right and left side of the fireplace opening to any adjacent
combustible wall should not be less than 8".
2) Ceiling Clearances:
The ceiling height should not be less than 42" from the top of the fireplace opening.
3) Mantel Clearances:
For clearances from top of heater to mantel or mantel supports see Figure 1.
4) Front Clearances:
No objects should be placed within 24" from the front of the fireplace opening. .
MINIMUM FIREPLACE DIMENSIONS FOR LOG SETS MANUFACTURED BY NEW
BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MASONRY
FIREPLACE AND PREFAB OR MANUFACTURED FIREPLACES.
NOTE: When using logsets with the Model 19HS heat shield see page 30 for clearances.
MODEL HEIGHT OF WIDTH OF WIDTH AT DEPTH OF
(CR, DX) OPENING OPENING REAR FIREPLACE
AT FRONT
18 17" 25" 18" 14"
24 17" 30" 24" 14"
30 17" 36" 26" 14"
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.
WARNING: “Cutting any sheet metal parts of the solid-fuel burning fireplace or
listed ventless firebox enclosure in which the unvented fireplace insert (log set) is to be
installed is prohibited.”
NOTE: “Smoke shelves, shields and baffles may be removed if attached by mechanical
fasteners.”
NOTE: “Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if
applicable) can be removed from the fireplace before installing the unvented fireplace
insert.”
NOTE: Glass doors must be in the open position, and screens must be in place in the
closed position when the appliance is in use.