Specifications

SuperDVR & WS 401 Series Cards
54
Alarm Output
Figure 4.15 Alarm output Configuration
[Video Loss]: Users can select alarm output for this option. For
example, users select alarm_out1 and alarm_out3 and remote
alarm for video loss. Then video loss of any channel will trigger
alarm_out1, alarm_out3
to show red light in the Alarm output
status panel (refer to
Figure 3.6 for reference), and the system
will give out related warning message to the terminals in List of
alarm output LAN terminals (refer to Figure 4.12)
[Disk Alarm]: when HDD available space is less than the set
value (refer to
Figure 4.9), it will trigger selected alarms.
[Sensor 1]: If users have mounted sensors, when the sensors have
been activated, then it will trigger the selected output alarms.
[Sensor 2] – [sensor 16] TD3004 card has maximum 4 sensors,
and TD3016 and TD3116 card have maximum 16 sensors.
[Motion 1]: Users can set motion detection alarm output by