4.2 To connect to the VingCard Vision server or workstation
4.2.1 To connect via TCP/IP
To make the RFID encoder accessible for VingCard Vision, the encoder must be
assigned with four parameters:
IP address
IP port number
gateway address
subnet mask
Before setting the above parameters in RFID Encoder Configuration Utility, the
USBXpress driver must be available for the RFID encoder to be able to connect and
perform the setup. When the RFID encoder has been configured with the four
parameters above, the encoder becomes backward compatible with the KDE
encoder which connects via TCP/IP only and has a static IP address.
Figure 12
1. Install the USBXpress driver according to Appendix B.
2. Double click on RFIDEncoderConfig.exe; if the encoder is
correctly connected to the PC and uses the USBXpress driver,
the serial number of the encoder should be shown in the upper
left window at USB; see example in Figure 12.
3. Follow the steps in section 5.2 to make the settings in RFID
Encoder Configuration Utility.