7. Web interface
(only applicable for Visionline)
If the parameters for the RFID encoder need to be modified to suit the network
where the encoder is located, this can be done either
via the configuration utility described in section 5.1
via the web interface described in the section To modify the encoder parameters.
To open the web interface, http://ipaddress must be entered in a web browser.
The encoder IP address is shown on the encoder display. Note: See Table 2 for
a description of the encoder parameters.
7.1 To modify the encoder parameters
Figure 27
1. Press the F button down to the right on
the back of the encoder (see Figure 5);
use a narrow instrument.
2. In the web browser, enter http://
ipaddress; the IP address to enter is shown
on the display at startup of the encoder.
See example below:
Note: If no DHCP server is available, use
the zero config IP address which is shown
on the display; see section 4.1.1 for more
information about zero config.
3. Make the desired changes in the RFID
Encoder Setup page; see example in
Figure 27.
4. If the server IP should be changed and
there is no DNS (Domain Name System):
Enter the applicable Server IP, OR
mark the radio button 'Enable'
for Announcement Broadcast;
this makes the encoder find the server.
5. When all desired changes have been done
in the RFID Encoder Setup page:
- Click Save.
- Click Reboot.
- Press the F button on the encoder again
to close the web interface.