19
ASSA ABLOY Hospitality
66 3081 004-23
3.1.1.1 TL Concentrator setup
The application server is set up to listen for GWs on port 7799. This is where
TLConcentrator will connect. TLConcentrator is set up to listen for GWs on port 7798
and to open sockets on the application server using port 7799.
To set up these parameters:
1. Go to Start/Run.
2. Browse to the installation folder, mark TLConcentrator.exe and click Open.
3. Add /config
Note: There should be a space before /
4. Click OK.
A Configuration dialog will be shown.
1. Let the default 7798 be at Listen Port.
2. State the host’s IP address at Host Address.
3. Let the default 7799 be at Host Port.
Figure 10
3.1.1.2 TL Concentrator monitor
It is possible to monitor the traffic through TLConcentrator using
TLConcentrator.exe /monitor.
1. Go to Start/Run.
2. Browse to the installation folder, mark TLConcentrator.exe and click Open.
3. Add /monitor
Note: There should be a space before /
4. Click OK. The following dialog (with example statistics) is shown.
Figure 11