20
ASSA ABLOY Hospitality
66 3081 004-23
3.2 Installing a gateway
Power and network connections should be made in a manner that will reduce the
chances of the device being unplugged.
The GW is powered by 5VDC using a plug in wall power adapter, or via power
over Ethernet.
For network connectivity, the GW requires an available Ethernet port and a
patch cord.
1. Open the System Monitor (SysMon), which is used for managing the online
network. To open SysMon, double click on SysMon.exe in the installation
folder.
2. Log on to SysMon: go to File/Log on and enter user ID and password.
At 'Operator card', choose the applicable card encoder. Click Enter.
3. If it is not open already, open SysMon's Online Network view at View/
Online Network. The Online Network view of SysMon shows all connected
GWs, RTs and ENs. Several useful commands are available by right clicking on
nodes; see sections 3.8.1-3.8.3 for more information about the different
commands.
Figure 12
4. Mount the GW in a convenient, out of the way location using the
VELCRO
®
strip.
5. Connect the network cable and power cable to the GW.
6. After approximately 30 seconds the GW will announce itself to the
server and appear as a new GW in the Online Network tree in SysMon.
Figure 13
7. Right click on the new GW to bring up the device option menu and choose
Edit Name.