Note: Due to a bug in BeeStack radio nodes of versions before 1.0.49, do not
use the Leave Network command for these older versions.
2. Important: Wait for 40 seconds to avoid confusing RT-A from which the EN has
deregistered.
3. Make sure that Forbid Joining has been chosen for RT-A and that Permit
Joining has been chosen for RT-B.
4. Present a Discovery card at the EN door lock (see chapter 5 Issuing a ZigBee
configuration card); the lock will chirp once and/or show a green LED signal,
depending on lock model. The EN will immediately begin to look for an available
parent, and since RT-A is in 'forbid joining' mode, RT-B will be its only option.
5. Once the EN has joined the correct RT, choose Forbid Joining on RT-B.
Note: The method above with Permit Joining can also be applied to RTs joining RTs,
RTs joining GWs, and ENs joining GWs.
3.8 Right-click menus in SysMon
When right clicking on GWs, RTs and ENs in SysMon, different choices appear
depending on what item you right click on. The different choices are described in
the following sections.
Note: Depending on what operator template that the logged on operator belongs to,
different operations in the right-click menus are greyed or not. The operations that a
certain operator template should be allowed to perform are set up in the client under
the SysMon alternative in the Operator Template Details dialog; see the client
setup manual for details.