User's Manual

Table Of Contents
47
ASSA ABLOY Hospitality
66 3081 004-23
6.2.5 Gateway list
The gateway list in the software contains all ZigBee gateways in the system.
To remove a gateway from the gateway list:
1. Double click on Gateways under the Lists tab in the navigation window.
Figure 49
2. Mark the gateway in the list and click Remove. The gateway will
automatically also be removed from the treeview in SysMon.
Note: If a * is shown in the dialog caption, one or more gateways have been added,
removed or renamed. In this case, press the Refresh button in the gateway list.
6.3 Setting in construction mode
If the network should be down for a period, e.g. during construction or renovation
of the hotel, the locks should be set in construction mode to reduce battery
consumption. Present a Construction Mode card at the locks (see chapter 5 Issuing
a ZigBee configuration card); each lock will chirp and/or a show a green LED signal,
depending on lock model. When the card is presented, the EN will be turned off.
If the EN in the lock is busy when the card is presented, instead a tick is heard and/or
a very short green LED signal is shown. In this case, make a new try by presenting
the Construction Mode card at the lock again.
To turn the EN on again, present a Discovery card at the lock; see chapter 5 Issuing a
ZigBee configuration card.